CAUTION - Operation of the B-TEL2 is guaranteed only if a qualified professional installs and programs
the device.
In the event of an alarm, all telephone devices connected after the dialer are isolated for the time
necessary to undertake the cycle of programmed calls. To restore the telephone line, interrupt the alarm
cycle as described in the "Stop Alarm by Keypad" paragraph.
The dialer display is normally turned off in a non-operating state. However, the occurrence of any malfunctions
will immediately be revealed on the display by a blinking letter, as described in the following (in order of priority,
in the event that several malfunctions are present simultaneously):
b
= Battery level low.
r
= External power failure.
t
= PSTN telephone line failure.
c
= Call running.
NOTE - It is necessary to enter the User Menu in order to perform KEYPAD OPERATIONS.
Acces User Menu
Access the User Menu key by entering the following formula:
where <User PIN> is a number 4 to 6 figures long (the User PIN is factory set at 0002).
When the User Menu is accessed, the letter
If an incorrect PIN or a PIN longer than 6 figures is entered, the speaker will emit an error sound (boop).
If 5 minutes elapse without a key being pressed at any point in the programming process, the dialer will
automatically exit out of the User Menu.
To exit the User Menu in advance, press the
Change User PIN
Change the User PIN (factory set at 0002) by entering the following formula:
where <New PIN> is a number 4 to 6 digits long.
Stop Alarm by keypad
Once an alarm situation has been detected, or in cases of a false alarm, the telephone dialer (and therefore
any calls, including those already underway) can be stopped by access the User Menu and pressing the
key on the keypad.
It is also possible to dedicate an alarm channel specifically to the Stop Alarm function. Ask the installer to
perform the wiring required for this option.
To ensure that the dialer has effectively performed the Stop Alarm, press the keypad keys. If the display remains
off, the function was successfully completed. If not, key in the Stop Alarm code again.
4 Channel telephone dialler
OPERATING YOUR SYSTEM
DISPLAY SIGN
DISPLA
DISPLA
DISPLA
DISPLA
KEYP
KEYP
KEYP
KEYPAD OPERA
KEYP
AD OPERATIONS
AD OPERA
AD OPERA
AD OPERA
A
U
will be shown on the display.
D
? @
Y SIGNALS
Y SIGN
Y SIGN
ALS
ALS
ALS
Y SIGN
ALS
TIONS
TIONS
TIONS
TIONS
C
<User PIN>
key when the display shows the letter
C
<New PIN>
U
.
C
49
G