Install In-Blower System

NOTE: The blower motor housing can be mounted using
4 holes from either the inlet side or the outlet side of the
blower.
A
A
A
A. Mounting holes
1
Position the in-line blower motor housing in its mounting
location and mark the 4 mounting hole locations.
2
Drill 4 mounting pilot holes using a ³⁄₁₆" (0.5 cm) drill bit.
3
Attach the in-line blower motor housing to the mounting
location with mounting (4) 6.3x60 mm screws and
(4)4x1.8 washers(Parts are included with the range hood
motor kit)
4
If removed, reinstall the blower motor assembly and
secure it with the screws previously removed.
5
If removed, reattach the motor electrical plug to the
connector on the blower motor assembly.
Complete Preparation
1
Determine and make all necessary cuts for the vent
system. IMPORTANT: When cutting or drilling into the
ceiling or wall, do not damage electrical wiring or other
hidden utilities.
2
Determine the location where the ¹⁄ ₂ " (1.3 cm) wiring
A
conduit will be routed through the ceiling or wall between
the in-line blower and the range hood.
3
Drill a 1¹⁄ ₄ " (3.2 cm) hole at this location.
4
Locate the electrical terminal boxes in the in-line blower
housing and range
and set the covers and screws aside.
A
5
Remove the electrical knockout from the in-line blower
housing and range hood (see the range hood installation
A
listed or CSA approved ¹⁄ ₂ " (1.3 cm) wiring conduit and
conduit connector.
6
With the range hood mounted (see the range hood
installation instructions), run the ¹⁄ ₂ " (1.3 cm) wiring
conduit between the in-line blower motor housing and the
range hood. Pull enough ¹⁄ ₂ " wiring conduit to allow for
easy connection to the terminal boxes in the in-line blower
housing and range hood.
hood.
Remove the terminal box covers
B
A. Terminal Box Cover
A
B. Knockout
instructions) to prepare for the installation of the UL
E
D
C
B
A. In-Line Blower Kit
B. Range Hood Terminal
Box
C. Power Supply wiring
Conduit
F
A
D. In-Line Blower Wiring
Conduit (not included)
E. In-Line Blower Terminal
Box
F. In-Line Motor Electrical
Plug Cable