RM7
D E S C R I P TI O N O F TH E CO NTR O L PA N E L
1
Alarm set-reset or temperature increase button
2
Alarm set-reset or temperature decrease button
3
Display
4
Green proper functioning LED
5
Red alarm LED
ALARM RESET
SET
1
2
U S I N G TH E CO NTR O L PA N E L
To switch the device on, press button 2.
To switch it off, press button 2 for 5 seconds.
The green LED 4 flashing intermittently indicates that the device is heating up and has not yet reached
its operating temperature.
As soon as the device reaches the set operating temperature, the green LED 4 remains steadily on; the
device is ready for use.
S E T TI N G TH E I NTE R N A L TE M PE R ATU R E
Press buttons 1 and 2 at the same time for 10 seconds to access the temperature adjustment function:
the display 3 with the set temperature will flash.
Use buttons 1 and 2 individually to increase or decrease the temperature setting.
When the desired temperature, between 32°C and 40°C, is reached, there is no need to press any
other button as the temperature setting is saved automatically.
A L A R M S
If the set temperature undergoes a variation greater than ± 1.5°C, the red LED 5 starts to flash intermittently,
together with an audible alarm (buzzer).
Check and eliminate the cause of the temperature variation and deactivate the alarm state by pressing
buttons 1 and 2 at the same time.