Edit Password; Switchboard Call Enable; Default.PRogramming; Programming.VIa.PC - Urmet BiBus sinthesi s2 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SEQUENZA DI ASSOCIAZIONE
ASSOCIATION SEQUENCE
N° DELLA POSTAZIONE (ID):
CALL MODULE NUMBER (ID):
SEQ.
NOMINATIVO
PULSANTE / CODICE
USER NAME
PUSHBUTTON / CODE
. 1
. 
. 3
. 4
. 5
The entire operation (booking and programming)
must be repeated for each module in the system,
unless the "Clone" function (see below) is
used.
The module will quit programming mode for the
following events:
• end.of.door.phone.programming.
• 10.minute.time-out.after.the.last.operation.
• pressing.the.red.programming.button.
• pressing. any. module. key. and. entering. the.
programming password.
How to associate 2/3 door phones in parallel in 2nd
edition.systems..
To install two or three door phones in one apartment
and make them both ring when a call is received,
press.
related to the user twice or three times with
the door phones in parallel when booking the door
phones. When you reach the apartment where the
parallel.door.phones.are.installed.according.to.the.
programming. sequence,. repeat. the. programming.
sequence.on.both.door.phones..
How to associate 2 door phones in parallel in 2nd
edition.systems..
To install two door phones in one apartment and
make them both ring when a call is received,
press.
related to the user twice times with the
door phones in parallel when booking the door
phones. When you reach the apartment where the
parallel.door.phones.are.installed.according.to.the.
programming. sequence,. repeat. the. programming.
sequence.on.both.door.phones..
Using.the."clone".function.in.1st.edition.systems..
A single association between calling station codes
and. respective. door. phones. can. be. made. in. 1st.
edition systems without switchboard and without
door. open. signal. function.. The. remaining. call.
stations can be clones of the first station (the master
station).and.copy.the.codes.associated.to.the.single.
users..To.enable.this.function:.
• define the master station as address "1" (where
to.make.the.association)..
• define all other stations as address "15".
Obviously,.all.names.must.be.programmed.on.the.
"clone".stations..
DS107-035

Edit password

This menu can be used to edit the password for
accessing.module.programming..
The following message will appear on the display:
PIANO
VARIE
FLOOR
VARIOUS
Enter the new 4-digit password and press
confirm.

Switchboard call enable

This. menu. is. used. to. enable. direct. concierge.
switchboard calls simply by pressing
function is only active when the door phone is in
day.mode..
The following message will appear on the display:
Press the scroll arrows to select and press
confirm.
DEFAULT PROGRAMMING
The device is pre-programmed as follows:
System.type:..
Station.type:..
Code.format:..
Station.number:..
Off-hook waiting time: 20s
Busy.time:..
Door.opener.time:..
To.restore.default.settings:.
• Disconnect module power.
• Hold. the. red. programming. button. pressed. and.
• Hold. the. button. pressed. for. approximately. 10.
• Release.the.button..
PROGRAMMING VIA PC
The call module can be programmed and configured
rapidly. by. means. of. a. PC. connected. to. the. serial.
port. (8). of. the. call. module. by. means. of. a. special.
wire Ref. 1072/57 (optional, not provided with the
product)..
The.B-BUS.PC.program.can.be.used.for.simple.and.
fast.module.programming..The.B-BUS.program.can.
be downloaded free of charge from the Urmet web
site (http://www.urmet.com).
Password:
New:
Call.key.
<YES> <NO>
power up the module.
seconds and wait for a tone.
9999
nd.edition.
main.
numeric.(0001–9999)
1
0s
pulse
. to.
.. The.
. to.
5