Installation and Maintenance Instructions
4. Attach a suitable 1-inch NPT hub or connector to conduit
entrance in bottom of light. For Type 4X/IP66 applications,
the hub or connector must be suitably rated (Myers
STTTB-2 or T&B
5. Set the light on the gasket and attach it to the mounting
surface with the provided 1/4-inch screws and washers.
6. For information on making the electrical connections, see
page 12.
Installing the Optional 22.5-Degree Reflector
The light is shipped from the factory with the standard reflector
that creates a horizontal lightbeam that is 90 degrees from the
vertical orientation. An optional reflector is available that reflects
the light beam at 22.5 degrees from the vertical orientation (see
Figure 1 on page 7 and "Accessories and Replacement Parts" on
page 16).
To replace the standard reflector with the 22.5-degree reflector:
1.
Disconnect power to the light.
2.
See Figure 3 on page 11. Remove the dome assembly by
grasping the die-cast ring attached to the dome and turning it
counter-clockwise.
3.
Loosen the two Phillips screws that retain the reflector.
4.
Gently lift the reflector from the assembly while being careful
to not drop the two screws.
5.
Position the new reflector onto the assembly and secure it with
the two screws.
6.
Reinstall the dome assembly.
7.
Reinstall power and test the light for proper operation.
10
®
H100-TB hubs are recommended.)
Model 371LEDX-120 Rotating Light
®