Setup for Stick Welding (SMAW)
•
Switch the Process SELECTOR SWITCH (1) on the front panel to the middle position.
•
Remove the MIG ELECTRODE POLARITY JUMPER (9) from the POSITIVE (+) and NEGATIVE (-) DINSE SOCKETS
(8 and 7).
•
Check the electrode packaging to determine the recommended polarity and connect the electrode holder and
ground clamp to the POSITIVE (+) and NEGATIVE (-) DINSE SOCKETS (8 and 7) accordingly.
•
Ensure the ground clamp has a good connection to the workpiece and is connected on clean, bare metal (not
rusty or painted).
•
Switch the unit ON with the ON/OFF SWITCH (11).
•
Set the amperage with the LEFT KNOB (4).
MATERIAL
ELECTRODE
(Wire)
TYPE
Regulation Knob
E6010
E6011,
Mild Steel
E6013,
E6014
E7018
Stainless Steel
E308L
Setup for TIG Welding (GTAW) with Lift Arc
Setting up the Equipment for TIG Welding (GTAW):
Lanthanated Tungsten 1/16" or 3/32" (MAX) recommended for use.
WARNING: TIG TORCH IS ALWAYS LIVE (ELECTRICALLY HOT).
the TIG torch is not in contact with or near conductive or grounded materials.
•
Switch the Process SELECTOR SWITCH (1) on the front panel to the bottom position.
•
Remove the MIG ELECTRODE POLARITY JUMPER (9) from the POSITIVE (+) and NEGATIVE (-) DINSE SOCKETS
(8 and 7).
•
Connect the TIG torch cable to the NEGATIVE (-) DINSE SOCKET (7) of the welder.
•
Connect the ground cable connector to the POSITIVE (+) DINSE SOCKET (8) of the welder.
•
Ensure the ground clamp has a good connection to the workpiece and is connected on clean, bare metal (not
rusty or painted).
•
Connect the TIG torch gas line to the gas regulator (argon gas only).
THE GAS FLOW IS MANUALLY CONTROLLED WITH THE KNOB ON THE TIG
TORCH. USE INERT GAS (ARGON) ONLY.
TURN ON GAS AT THE GAS REGULATOR, THEN OPEN THE VALVE ON THE TORCH
HANDLE, CHECK FOR GAS FLOW AND ADJUST FLOW RATE AS NEEDED.
•
Fix the tungsten electrode so that it protrudes approximately ¼ inch from the torch nozzle.
•
Ensure the TIG torch is safely away from all conductive materials.
•
Switch the unit ON with the ON/OFF SWITCH (11).
•
Set the amperage with the LEFT KNOB (4).
•
Open the gas valve on the torch handle.
•
Initiate the weld arc with a lift arc technique.
•
Close the gas valve on the torch handle after post-weld flow has been completed.
REMEMBER TO CLOSE THE VALVE ON THE GAS CYLINDER IMMEDIATELY AFTER
ALL WELDING IS COMPLETED.
20
140 MP STICK SET-UP CHART
1/16" (1.6 mm)
5/64" (2 mm)
Left Knob
–
2-5
–
–
CANNOT WELD ALUMINUM
WWW.FORNEYIND.COM
ELECTRODE DIAMETER
3/32" (2.4 mm)
Left Knob
Left Knob
–
6-9
5-8
6-9
–
8-10
–
7-10
1/8" (3 mm)
Left Knob
10
10
10
8-10
Use caution and ensure