3.8
Safety features of the battery pack
The battery pack is protected against:
Short-circuit
Deep discharge
Over- and under-voltage (of the battery pack and the individual cells)
Over-current during charging and discharging
Overcharging
Over temperature (of individual cells and electronics)
Charging and discharging outside the allowed temperature range
4

First use

4.1
General
Examine the equipment for completeness and damage. Do not use the equipment if it is damaged;
in that case contact the Holmatro dealer.
Make sure the on/off switch is attached to the pump with a cable.
Before first use, always charge the battery pack completely. Refer to section 5.12.
Put the battery pack in the battery pack fitting / adapter fitting until the battery pack locks.
Make sure that the battery lock operates correctly.
5
Operation
5.1

System operation

A system is an assembly of a hydraulic pump, hose(s), and one or more tools. This hydraulic pump is
driven by a battery pack or from an external electric power source. This pump displaces hydraulic oil
and is capable of building up pressure. The hydraulic pump has a female Core coupler. The hose is for
transporting the hydraulic oil between the pump and the tool.
The hose is the piece of equipment that connects the pump to the tool, thus creating a closed system.
A cable connects an on/off switch to the pump.
The motor operates at constant rpm.
5.2
Carrying position

Refer to Fig. 3

This hydraulic pump is designed to fit in a backpack. Make sure the battery pack is on the top of the
pump. The CORE coupler is at the bottom of the pump.
5.3
Installing the battery pack
Put the battery pack in the battery pack fitting / adapter fitting until the battery pack locks.
5.4
Connecting to an external power source
See Fig. 6.
Apart from using the battery pack, the tool can also be connected to the mains by the special mains
connector. Use only the original mains connector for this purpose.
36