Air Circulation - Palazzetti ECOPALEX Serie Manual De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para ECOPALEX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.4.3
Housing with optional ventilation kit 680 m
For existing wood inserts, there must be a compartment
under the wood insert base to house the fan. Its
dimensions must be as indicated in the gure
(Fig. 5.5 - 5.5.1)
5.4.4
Air intakes with optional ventilation kit 680 m³/h.
In addition to the combustion air intake ("C" - g. 5.6), the
following air intakes must be provided for the fan:
Room air intake to heating circuit fan, located laterally
to the cladding (diameter 15 cm) with grille.
Room air intake (connected as (
alternatively connected to an adjacent room (with the
exception of the bathroom, kitchen, bedroom) (diameter
15 cm) with grille (-5.7-).
Depending on the solution adopted, during the dry test
installation it is advisable to mark the position of the air
intakes on both the cladding and the external wall.
The fan air intakes can be provided with an adjustable
closure shutter, and must be equipped with anti-insect
screens.
It is indispensable to clean lters or ne mesh grilles
periodically because they may become clogged.
6

AIR CIRCULATION

There are three possible solutions to hot air
circulation
:
NATURAL CIRCULATION (STANDARD)
(supplied with the machine)
NATURAL CIRCULATION WITH HOOD
(with the Natural ventilation with hood kit)
FORCED CIRCULATION WITH HOOD
With the Centrifugal fan with adjustment unit kit and
Ventilation with hood kit.
INSTALLATION
3
/h
(-5.6-)), or
00 477 0152 -04/2017 - PALAZZETTI - PN - I
>50 cm
C
A
C
TALY
10
>50
>35
- 5.5 -
F
. 5.5.1
IG
B
- 5.6 -
D
- 5.7 -
35

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ecopalex 64Ecopalex 66Ecopalex 76Ecopalex 78Ecopalex 88

Tabla de contenido