www.mediclinics.com
Firmly screw the base of the device to the wall (Figure 6), ensuring that the 4 silent-
blocks are correctly placed between the base and the wall.
Connect the electrical cables to the hand dryer's terminal strip. Connect the cables
corresponding to the two phases (N and L) and to earth in the corresponding sockets of
the terminal strip, as indicated by the engraved letters (Figure 7).
Figure 7.
Figure 8.
During this process of fitting the casing to the base take care not to damage the
electronic circuit that is below the hand dryer's nozzle (Figure 11).
It is also very important to ensure that once mounted and screwed to the base the
casing has the plastic protector correctly placed on the lower inverted "U" shaped
window (Figure 12).
Figure 11.
NOTE: contemplate a minimum distance of 400 mm (15,80") away from ledges, marble
tops or wash basins (Figure 13). Avoid as much as possible the presence of reflecting
surfaces within the area of the hand dryer's IR sensor.
When
making
these
disconnecting from the power grid with a minimum contact
separation of at least 3 mm (0,12") for all poles. These
disconnection means must be incorporated into the fixed
installation.
The hand dryer must be installed against a solid surface only (wall,
partition, or similar).
Carefully place the casing on the base of the device. To do so
place it over the base with a slight incline from top to bottom, in
such a way that the tab in the casing correctly inserts into the
corresponding slot in the base (Figures 8 and nº 9).
Place the screws for fixing the casing to the base, fixing them
tightly using the special spanner provided (Figure 10).
Figure 9.
Figure 12.
connections
contemplate
Figure 10.
Figure 13.
means
for