10.
Fit the front of the chimney, H-11, to the sides of the chimney. Fix it
to the lower tabs using two M-6x35 screws with washers and nuts.
11.
Fit the H-01 baseboard to the front of the base. The vertical tab will
limit with the lower part of the frame. Fix to the frame using the
vertical tab by means of two M-6x25 screws with washers and nuts.
12.
Fit the hood by fixing the internal tabs or side, front and back edges
that form the chimney. Fix to the sides of the chimney using two M-
6x30 screws with washers and nuts.
13.
Fit the draw regulation valve, L-020, in the position you find most
suitable, on the front or on the side. You will have to open the gaps
for the tube in the collar ring.
14.
Fit the grill in the base.
15.
Fit the protection over the mouth of the hearth. The sides of the
protection cover must fit into the tabs located on the sides.
16.
Introduce the ash pan through the front of the baseboard, H-01.
Important!! When assembling, seal all joints between parts with refractory
putty.
Do not tighten the screws until the last piece has been placed (the hood).
Do not place all the weight of the chimney on the device.
3.2 INSTALLING
(accessory)
1.
Fit the Franklin type columns to the frame by placing them on the
baseboard. Fix them to the frame by means of the two enamelled
round head screws, l/4x45mm, with a washer and nut. DO NOT
TIGHTEN AT PRESENT.
2.
Fit the FRANKLIN front piece on the top of the frame and rest it on
the top ends of the columns. Fix the frame using the three brass
screws, nuts and washers.
Tighten the columns.
3.3INSTALLING THE THERMAL GLASS DOOR (accessory)
Instructions are provided with the glass door. It requires drilling the sides
of the hearth matching the sides of the door and is only advisable for
hearths that have been installed with an air chamber.
In the case of built-in hearths, the door can be attached by simply gluing it
to the frame using refractory putty.
3.4DIAGRAM OF THE LINING
VERSION "A": CONVECTION with external air intake (clean air).
VERSION "B": CONVECTION with local air intake (recirculation of the
same air)
THE
FRANKLIN
STYLE
FRONT
- 24 -
PIECE