temperatures (varnish, paint...). Ensure that the top hot air grilles
are not installed on combustible elements.
6. Protect your hands with a glove or other insulating material
because, during operation, the handle will get hot.
700
REPLACING THE POWER SUPPLY CABLE
If the power supply cable is damaged, it must be replaced by the
manufacturer or by the S.A.T. or by qualified personnel, in order to avoid
risks.
Industrial Hergóm, S.A. rejects any liability derived from a faulty
installation or incorrect use and reserves the right to alter its products
without prior warning.
Any liability due to manufacturing defects will be subject to the criteria and
verification of the company's experts and will be limited to the repair or
replacement of its products, in accordance with the warranty agreement
that comes with each product.
When installing a H-02/22 Heater Hearth, with a closed expansion vessel,
a number of safety requirements must be considered.
1. When installing the radiators, do not place zone thermostatic valves
on all radiators. Part of the installation (radiators) must be open so
that the hearth may be able to dissipate any overheating.
2. It is obligatory to place a safety valve, regulated at a pressure of 3
bar. The installation should be performed at a pressure of 1 bar.
30
- 37 -
900
300