Descargar Imprimir esta página

Publicidad

Problem or Symptom
Tool will not fully drive fastener.
Tool does not advance fastener.
Screws "kick-out" or miss-drive during use.
Bit will not install.
Bit slips off screw or screw is driven at an angle.
Fastener jams.
Slide mechanism "sticks" or returns slowly.
Tool overheats.
Pushing force becomes excessive.
TROUBLESHOOTINg
Probable Cause
»
Bit is worn.
Power capabilities of the tool have been
»
exceeded.
»
Tool is in reverse.
Incorrect bit installed.
»
Depth of drive not set properly.
»
»
Screw length is improperly set.
»
Return spring is weak.
»
Defective collation material.
Defective slide body.
»
Screw strip is jammed in guide track.
»
Screw length improperly set.
»
»
Incorrect bit installed.
»
Defective or damaged feed system.
»
Bit not properly inserted into drive shaft.
»
Clutch teeth not aligned.
Not a Senco bit.
»
Tool slid forward during drive.
»
Tool is misaligned.
»
Bit is worn or broken.
»
Nosepiece is worn or damaged.
»
Screw length improperly set.
»
Defective collation material.
»
Nosepiece damaged or bent.
»
»
Screw partially driven into collation material then
feed system released.
»
Debris build-up in mechanism.
»
Weak return spring.
»
Bit sticking in collation material.
»
Drive application requires too much torque.
Slide body is worn.
»
»
CAM screw is loose or damaged.
Debris build-up in mechanism.
»

Corrective Action

»
Replace bit.
Discontinue use in that application.
»
»
Switch tool to forward.
Ensure correct bit type and length are installed.
»
See pg. 7 for proper adjustment.
»
»
See pg. 6-7 for proper adjustment.
»
Replace or return to authorized service center
for repair.
»
Use Senco branded fasteners for optimum
performance.
Replace or return to Senco authorized service
»
center for repair.
Ensure strip slides free in guide track.
»
See pg. 6-7 for proper adjustment.
»
»
Ensure correct bit type and length are installed.
»
Return to Senco or Authorized service center for
repair.
»
See pg. 6 for proper adjustment.
»
Pulse trigger while holding back release button.
Use only the appropriate Senco bit.
»
If wood nosepiece is used, replace sandpaper
»
pad.
Hold tool firmly while driving.
»
Return to Senco or Authorized service center for
»
repair.
Replace bit.
»
Replace or return to Senco authorized service
»
center for repair.
See pg. 6-7 for proper adjustment.
»
Use Senco branded fasteners for optimum
»
performance.
Replace or return to Senco authorized service
»
center.
»
Remove jammed screw with fingers or pliers and
resume use.
»
Clean mechanism.
»
Replace or return to Senco authorized service
center for repair.
»
Use Senco branded fasteners for optimum
performance.
»
Always attempt to store screws in cool dry place
before use. Overheated collation can get soft and
cause a delay in feed system return.
»
Discontinue use in that application.
Replace or return to Senco authorized service
»
center for repair.
»
Tighten or replace CAM screw.
Clean mechanism.
»
15

Publicidad

loading

Este manual también es adecuado para:

Senco ds320