1. n
1.1 g
enerAl nOtes On sAfety
This operation manual is applicable for the machine BEW
3.
The machine may only be handled by personnel
who are qualified.
1.2 u
se Of the mAchine fOr PurPOses fOr
which it is intended
The machine is suitable for all machining operations need-
ing axial force and torque like drilling, reverse drilling, chip
breakage, countersinking, and reverse countersinking.
This machine is specifically ideal for plant construction.
1.3 i
ncOrrect use
All uses other than those described under section
1.2 are regarded as incorrect use and are there-
fore not admissible.
1.4 d
eclArAtiOn Of incOrPOrAtiOn
The manufacturer Otto Suhner AG of Industriestrasse 10,
CH-5242 Lupfig, hereby declares for the partly completed
machinery (see reverse side for type and serial no.) that
the following fundamental requirements of the Directive
2006/42/EC are applied and fulfilled in accordance with
Annex I: 1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.2, 1.3.7, 1.3.8.1, 1.5.1,
1.5.4, and 1.6.1. Technical documentation was generated
for the partly completed machinery in accordance with
Annex VII of the Machinery Directive. Document Agent:
I. Sebben. Authorised sites are provided with this techni-
cal documentation in paper or electronic form on justified
request. This partly completed machinery may be put into
operation only when the machine in which the partly com-
pleted machinery is to be incorporated has been ascer-
tained to fulfil the conditions under the Machinery Direc-
tive. CH-Lupfig, 12/2017.
I. Sebben/Division Manager
2. c
2.1 A
ssemBly instructiOns
Maximum admissible machine fastening error.
The machine is fastened at the bores provided in
the housing.
Screws of quality grad 8.8 must be used. The starting tor-
que for the holding down bolt is maximum 10-12Nm.
22
s
otEs on
aFEty
ommissioning
Connect the cables only after the machine has
been completely installed.
Install the frequency converter according to the
instructions given in the frequency converter oper-
ating manual.
2.2 c
Onnecting the POwer tO the mAchine
2.2.1 s
ensOres
The drilling unit is equipped with inductive sensors which
monitor both the front and rear stroke end positions. The
sensors have been adjusted in the factory.
2.2.2 P
neumAtic AdVAnce
Attach air hoses (polyurethane hoses Di=4 mm, max.
pressure 7 bars, -35 to 60 °C ) to the installed pneumatic
connections.
W
ithOut chip reMOVaL
Stroke «back» (1). Stroke «forward» (2).
Type: PNP
Voltage: 10-30 DCV
Output current: 200 mA