c1. Hold the left key pressed and press the right
key to leave the programming operation
c2. Press the right key to switch to
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alter-
nates between the menu title and the current
menu item setting. After pressing any key,
only the menu item setting is displayed.
f. Pressing the right key will switch the menu
item setting to the next value.
If figures are to be input (e.g. when setting
the scaling factor), select first the digit using
the left key, and then set the value using the
right key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title "EndPro" allows the user,
when selecting "Yes", to exit the programming
menu and to store the new values. If "no" is
selected, the programming routine is repeat-
ed, the latest values set remaining active.
They can now be checked again or modified.
4. Programming routine
The programmable parameters of the device are
described below, in succession. The device is
fully programmed after one pass of the routine.
The first values stated correspond to the factory
settings.
4.1 Polarity of the inputs
2
.
npn: sinking sensor
pnp: sourcing sensor
4.2 Switching on the 30 Hz filter (INP)
4.3 Decimal point setting
4.4 RESET Mode

4.5 End of programming

* where bounce occurs, e.g. with contacts
The filter provides input
damping*
30 Hz filter off (f max )
30 Hz filter on
The decimal point determines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0
one decimal place
0.00 two decimal places
0.000 three decimal places
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
The programming routine is
repeated once more. The
values set until now can be
checked and modified.
The programming routine
will be exited and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.