DISPLAY
DATA
SPiA
FLSh
W.L.
no
LP.PA
no
Si
Strt
StAn
no
AP.Ch
PrES
oroL
Sto P
no
ProS
invE
Fot 1
no
AP.Ch
Fot 2
CFCh
Ch
no
Ft.tE
no - Si
FUNCTION
Setting low voltage exit lights
This menu makes to possible to set the flashing exit function
Flasher operation (fixed frequency)
Indicator light operation: Indicates the status of the gate in real-time.
The type of blinking indicates the four possible conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
Not used
Blinker during pause time
Function deactivated
The blinker will be on during the pause time too (gate open with automatic
closure active).
Activation inputs (START and START P.)
This menu allows selecting input operation modes (see chapter 4.2)
Standard mode
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
Open/Close command
Manned operation
Timer mode
Stop Input
The input STOP is not available (ignored by the control unit)
The input STOP stops the gate: pressing the command START the gate
continues the motion
The command STOP stops the gate: at the next START the gate starts moving
in the opposite direction
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to say,
photocells active both during the opening and closing phase
Input disabled (ignored by the control unit)
Input enabled
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase
nput enabled even at standstill gate too: the opening movement does not
start if photocell is interrupte
Input enabled for the closing phase only
WARNING: if you select this option, you must disable photocell test
Input disabled (ignored by the control unit)
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
StAn
46
DEFAULT MEMO
FLSh
no
StAn
no
no
CFCh
no