RING GUARD

GASKET INSPECTION (FIG. 9)

The recommended interval between inspections shall not exceed six months for components that are
detached for cleaning and sanitizing (all the gaskets in the images).
The inspections must be made by the manufacturer or its authorized service agent.
GASKET BETWEEN HANDLE/SPACER
AND SPACER/MEAT PUSHER
GASKET
BETWEEN THE
PRODUCT TABLE
AND THE
THUMB GUARD
PROTECTION ON
THE SWITCHES
The slicer must be removed from service until repaired by the manufacturer or its
authorized service agent if any gasket or seal is found to be damaged, or missing.
KNIFE
Fig. 7
GASKET BETWEEN
THE PRODUCT TABLE
AND THE EXTENSION
GASKET BETWEEN THE
HANDLE AND THE
PRODUCT TABLE SUPPORT
Fig. 9
– 7 –
Fig. 8
GASKET BETWEEN
THE PRODUCT TABLE
AND THE SUPPORT