4.16 Opening command setting
It is possible to change the functioning of the open/stop/close command to only open
Press"+" to display "9"
Note: in order to exit the programming and save the parameters push P button for 5 seconds.
4.17 End of programming
Warning: this final step must be done otherwise information will not be saved.
It is possible to abandon the programming phase and save data in any step on the functions menu from 4.7 to 4.17 in the following mode:
Press "P" in any function from 1
to 9 until the display shows the
set value
4.18 Save and deletion of transmitters
Follow the procedure below to memorize ROLLING CODE transmit-
ters. To save FIX CODE transmitters follow the paragraph 4.12, then
after memorize transmitters as indicated here below.
1. Save
• Press the S button until "0" appears
• Release the S button
• Press the button of the transmitter to be memorised
• The "0" on the display disappears, the transmitter has been saved
• For the next transmitters (maximum 20 ) repeat the procedure for
each single transmitter
BUZZER SIGNAL
1 beep
2 beeps
3 beeps
2. Deletion of a single transmitter
• Press and hold the P+S button
• Press the button of the transmitter to be deleted until the control unit
emits a beeping sound
• Release the transmitter button
• This procedure will delete all the buttons regarding that transmitter
3. Deletion of all transmitters
• Disconnect the 230 Vac power supply
• Press the S button
• Reconnect the 230 Vac power supply holding the S button for 5 sec-
onds until you hear the 2 beep sounds of the control unit
Press "P", the display shows
"0" to indicate that the step/step
command has the Open/Stop/
Close function (default setting)
Press and hold "P" for 5 sec-
onds to save the modifications
made
MEANING
code memorized
code already memorised
memory full
Press"+", "1" appears to indicate
that the step/step command can
only open
A beep followed by a sliding "0"
indicates that the programming
procedure has concluded suc-
cessfully
4. Wall switch and courtesy light programming
• Push S button until "0" will appear
• Release S button
• Push once again S button until "0" will start to flash
• Release S button
• In order to switch on the courtesy light push the remote control
button or wall switch button to be memorized
N.B: Once activated the courtesy light will stay on for 180 sec; in
case of reactivation the courtesy light counter will re-start from zero.
It is possible to memorize just one button with the courtesy light
function.
By enabling this function, the
Step/Step command permits
opening by accepting only re-
opening during closing.
With the function "7=1" auto-
matic closure enabled at each
command the automatic closing
time is updated
With the function "7=0" automat-
ic closure disabled with the door
open it is possible to reclose it
using the step/step command
EN
23