Note: The safety distance between the induction hob and the cabinet or
extractor hood above the induction hob must be at least 760 mm.
A(mm)
Before installing the induction hob, make sure that
The countertop surface is smooth and level, and no structural elements
interfere with space requirements
The hob is made of a heat-resistant material.
If the induction hob is installed above an oven, that the oven has a built-in
cooling fan.
The facility will comply with all authorization requirements and applicable
standards and regulations.
The electrical installation complies with local safety rules and regulations
and incorporates a suitable isolation switch or circuit breaker that provides
a total disconnection from the electrical network.
The isolating switch or circuit breaker must be adequate and provide a
3mm air gap contact separation on all poles (or on all active [phase]
conductors if local wiring rules allow this variation of requirements )
The isolating switch or circuit breaker is easily accessible to the user.
Consult with a licensed electrician or local authorities regarding installation
and statutes, if in doubt about installation.
Use easy-to-clean, heat-resistant finishes (such as ceramic tile) for the wall
surfaces surrounding the countertop.
B(mm)
760
50 mm
C(mm)
D
30 mm
Air inlet
19
E
Air outlet
10 mm