ATTENTION!: Do not load the cabinet top with boxes, packages or other objects (Rif. 8).
Keep the doors open as briefly as possible during loading.

12.Defrosting and water discharge (Fig. 7)

The Brema 5 - Brema LF line of refrigerated cabinets is equipped with an electric defrost system (which
stops the refrigeration cycle - twice a day for 30 min - and armored heating elements).
To drain the defrosting water follow the procedure below:
- provide a slightly sloping drainage in the floor;
- install a drain-trap between the cabinet draining duct and the floor connection;
- hermetically seal the water draining area of the floor.
This procedure prevents the risks of bad smell inside the refrigerated cabinet, dispersion of refrigerated
air and possible malfunctioning due to humidity.
N.B.Periodically have a qualified installer check that the hydraulic connections are in a perfect
state.

13.Anticondensation and antifogging device

To prevent fogging due to condensation, low power electric heating elements are installed on the parts
most subject to the problems such as: the thermoinsulating glass of the doors, the frames and struc-
ture, the windows on the sides, etc.

14.Illumination

The interior illumination of the cabinet is obtained by means of fluorescent lamps located vertically
behind the uprights of the cabinet structure. The light switch is located in the box on the power panel.
The reactors, starters and condensers are located on the roof of the cabinet.
Brema 5 - Brema LF - 2 Doors: no. 3 lamps
Brema 5 - Brema LF - 3 Doors: no. 4 lamps
Brema 5 - Brema LF - 4 Doors: no. 5 lamps
Brema 5 - Brema LF - 5 Doors: no. 6 lamps
OPTIONAL: For greater energy savings, the cabinet can be ordered complete with low
consumption LED lighting. This allows for:
- 70% savings on lighting consumption
- reduced refrigerator load
- duration of lights: more than 6 years
- uniform lighting colour and intensity on all doors at all times
- improved lighting as temperature decreases.

15.Lamp replacement

To replace the lamps proceed as follows:
- Disconnect the power to the cabinet;
- Remove the fastening screws A on the protective casing;
- Remove the caps B, and the protective casing C;
- Turn the lamp D by about 90° (until it clicks) and remove it from the socket;
- Replace the lamp;
- Replace the casing and caps and fasten in place with the screws;
- Connect the power.

16.Maintenance and cleaning

WARNING: BEFORE CARRYING OUT ANY MAINTENANCE WORK OR
CLEANING, FIRST DISCONNECT THE UNIT FROM THE VOLTAGE SUPPLY
BY MEANS OF THE GENERAL SWITCH. WE RECCOMEND WEARING
WORKING GLOVES WHILST CLEANING, TO PROTECT THE HANDS.
Food products can deteriorate due to germs and bacteria.
Respect of the rules of hygiene is indispensable to ensure the safeguarding of consumer health and
respect of the cold chain of which the grocery store is the last controllable link. Cleaning of the refrige-
rating cabinets is distinguished as follows:
Cleaning the external parts (Daily / Weekly)
- Clean all the external parts of the cabinet weekly using neutral detergents for domestic use or soap