Troubleshooting; Maintenance And Repair; Notices; Information For Ordering Spare Parts - Sulzer DP 200-70 Manual De Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Dispenser DP
5.

Troubleshooting:

Problem
Potential Cause
Plunger discs cannot
Cartridge not fully
enter the cartridge
inserted in cartridge
bed
The cartridge cannot
The plunger discs are
be removed from the
still in position inside
.
dispenser
the cartridge
6.

Maintenance and repair:

Notices

All maintenance and repairs must only be carried out by
sites authorized by the manufacturer and exclusively by
qualified and suitably trained personnel.
Always disconnect the compressed air supply from the
dispenser during maintenance and repairs.
Never open the pneumatic drive unit. If the pneumatic
drive unit is or appears to be in need of maintenance or
repair, contact a Sulzer Mixpac authorized Service Center.
Keep the dispenser clean at any time. Failure to do so
may result in malfunction of dispenser or bodily
injury.
Do not use aggressive cleaning products to clean the
surface of the device.
2009-03 (V 2.0)
22905825v3
Sulzer Mixpac AG
Remedy
Check that there is
no foreign matter in
the cartridge bed.
Push the cartridge
fully down into the
cartridge bed. Mind
your fingers.
Press the red button
to fully retract the
.
plunger discs to the
back end-stop.
10
Dispenser DP

Information for ordering spare parts:

When ordering spare parts, please provide the following information:
Serial number
Dispenser type
Product description / spare part
7.

Technical data:

Operating pressure:
max. 6 bar (max. 87 psi)
Compressed air supply:
max. 8 bar (max. 120 psi)
Air requirements:
ISO 8573-1 2.4.2
Pressure adjustment:
Infinitely variable
Sound level:
83 dBA
Weight:
DP 200-70
DP 400-85
DP 400-100
8. Codes and standards applied:
8.

Standards applied:

2006/42/EG:
Machinery Directive
8.1 Codes:
97/23/EC:
Pressure Equipment Directive
ISO 8573-1:
Compressed air quality classes
2006/42/EC: Machinery Directive
8.2 Standards:
EN ISO 8573-1:2000 Compressed air quality classes
Original manual written in German
2009-03 (V 2.0)
22905825v3
Sulzer Mixpac AG
1.6 kg
2.2 kg
2.4 kg
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dp 400-85Dp 400-100

Tabla de contenido