Press
key to return to normal mode from counting mode.

7. Animal Weighing and stable detection

Drive the animal on to the platform. If the weight stabilises within a few seconds, the weight is stored.
If the weight now changes, the new weight is recorded and stored.
Animal weighing mode can be switched on or off by setting the parameters.
To set stable detection, switch on the scale.
Press the
key during the start-up procedure.
The display shows pn
Press
,
Press
until display shows p4 oth
Press
key to confirm and then press
If necessary, use the
. When the setting is On, stable detection is in use.
Display shows Rag with set values. If necessary, adjust these using the
with
.
RAG: Set the number of parts* in which the stable weight is determined compared with the
average weight recorded. Setting options: 1-2-5-10-15-20-25 and 50.
See explanation on setting of parts at the bottom of this page.
Assume 1 part of 0.5 kg has been chosen and 5 is selected here: the range is 2.5 kg
(5 x 0.5 kg) from the average weight recorded.
The higher the number of parts is set, the faster the stable weight is determined but the more
inaccurate the weighing.
Display shows Tim with set values. If necessary, adjust these using the
with
.
TIM: Set the number of times that the weight must have been in the range (RAG) to lock a stable
weight. 10-20-30-40-50-60-70-80-90.
The higher the TIM, the longer it takes to determine the stable weight but the more accurate the
weighing.
and
, display shows poch
key to select until the display shows On and confirm again with
to select Ani
key and confirm
key and confirm
29