Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 85
P4 oth
Lock
anm
Ps unit
Kg / lb lb-oz / tj / hj
P 6 xcl
P7 rst
P8 uw b
U w b

13. Error Codes

Error Message
Description
-----
Maximum load exceeded
Err 1
Incorrect date
Err 2
Incorrect time
Err 4
Zero setting error
Err 5
Key board error
Err 6
A/D value out of range
Err 9
Unstable Reading
Err 17
Tare out of range
--ol--
Over range
Fai l h / fai l l
Calibration Error
Err p
Printer error
Ba lo / lo ba
Battery low
40
To set keypad lock
Options: on / off
on
Rag
tim
nlk
off
To turn animal function on or off
To set unit.
Options; on / Off . When the unit option is on, that unit
can be active. Tj and Hj cannot be used at the same
time.
External calibration
To reset the parameter back to the factory settings
On
To turn Bluetooth function on or off
off
1 / 2 / 5 /10 /15 / 20 / 25 / 50
10 / 20/ 30/ 40/ 50/ 60/ 70/ 80/ 90
1 / 2 / 5 /10 /15 / 20 / 25 / 50
Solution
Unload or reduce weight
Enter the date using format
"yy:mm:dd"
Enter the time using format
"hh:mm:ss"
Zero setting range exceeded due to
switching on. (4% max)
Make sure platform is empty.
Check the keys and connectors.
Make sure platform is empty and check
that pan is installed properly. Check the
load cell connectors.
Check any air variation, vibration, RF
noise and points of contact.
Check the load cell connectors.
Remove the load and restart scale.
Remove the load.
Re-calibrate
Re-calibrate
Check the printer and settings
Recharge battery, check the voltages.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

4309606

Tabla de contenido