Hilti PSA 200 Manual De Instrucciones página 5

Ocultar thumbs Ver también para PSA 200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Note
The PSA 200 application cannot be used unless your contact data and a valid activation key have
been entered.
4.3 Settings
1. Select the desired language, the desired country and the units you wish to be displayed.
Note
When operating a brand new device you will first be requested to select the country-specific
settings.
2. Confirm the settings you have made by pressing the OK function button.
Note
By pressing Skip you can postpone making these settings until the next time the PSA 200
application is started.
5 Operation
5.1 Displaying the operating instructions
1. Press the ? symbol at top right.
Note
The operating instructions will be shown in the right context in the display. You can then browse
through the complete operating instructions.
2. To close the operating instructions, press the Back function button.
5.2 Main menu
The PSA 200 application starts with the main menu, which can also be accessed at any time by pressing the
Home button at top left of the screen. From there you can also access the project management and settings
screens.
5.3 Project management
Using the functions accessed from the Projects submenu you can manage projects, display and analyze
previously recorded scans and import new data.
5.4 Importing PS 1000 X-Scan projects and data
1. Use the PSA 52 cable to connect the PS 1000 X-Scan.
2. Press the Import function button and then select the PS 1000 X-Scan.
3. Either use the check boxes to select one or more projects or tap a project to show the scans it contains.
These scans can then also be selected by way of the check boxes.
4. Confirm your selection by pressing the OK function button and, if individual scans have been selected
(see point 3), then select the target project on the PSA 200 tablet.
5. The selected objects (projects or individual scans) will then be imported.
5.5 Importing PS 200 S Ferroscan projects and data
1. Insert the PSA 56 infrared adapter in a USB port on the PSA 200 tablet.
2. Position the PS 200 S opposite the PSA 200 tablet so that the IR interfaces are facing each other directly.
3. Press the Import function button and then select the PS 200 S.
4. Select the project into which the scans from the PS 200 S are to be imported.
5. All the scans from the PS 200 S will then be imported into the selected project on the PSA 200 tablet.
5.6 Analyzing scans
1. Select the desired scan from a project.
◁ The scan is then displayed.
2. Use the function button to set the display mode to 2D or 3D.
Printed: 16.11.2016 | Doc-Nr: PUB / 5300608 / 000 / 01