Technical Data - EUCHNER CMS Serie Manual De Instrucciones

Unidades de evaluación
Ocultar thumbs Ver también para CMS Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Evaluation Units CMS-E-ER

Technical data

Parameter
Housing material
Dimensions
Weight
Ambient temperature
Storage temperature
Degree of prot. acc. to EN 60529
Degree of contamination
(external, acc. to EN 60947-1)
Mounting
35-mm mounting rail acc. to DIN EN 60715 TH35
Connection
Operating voltage U
B
Internal fuse (operating voltage U
)
B
Safety contacts
Switching voltage U
max.
Current consumption at DC 24 V
Switching current I
at 24 V
max.
Switching current I
at 24 V
min.
Breaking capacity P
max.
External contact fuse (safety circuit)
acc. to EN IEC 60269-1
Auxiliary contact
Switching current I
at DC 24 V
max.
Utilization category
according to EN 60947-5-1
AC-1
AC-1
AC-15
AC-15
DC-13
Switching load acc. to UL Class 2
Rated insulation voltage U
i
Vibration resistance
Mechanical operating cycles, relay
EMC compliance
Approval
LED indicators
Risk time according to EN 60947-5-3
Reliability values according to EN ISO 13849-1
as a function of the switching current
at 24 V DC
Number of switching cycles/year
Mission time
Category
1 read head
>1 read head
Performance Level (PL)
1 read head
>1 read head
PFH
d
1 read head
>1 read head
1) I
= max. switching current per contact, U
e
Value
Polyamide PA6.6
114 x 99 x 22.5
0.22
0 ... +55
-25 ... +70
Terminals IP 20 / housing IP 40
2
Connection terminals
24 ±10%
750 (automatically resetting fuse PTC)
2 NO contact
240
10 ... 110
3
10
720
4
1 NC contact
1.5
I
U
1)
1)
e
e
3 A
230 V
3 A
24 V
0.9 A
240 V
0.9 A
24 V
1.5 A
24 V
Input:
24 V AC/DC
Output:
30 V AC
24 V DC
250
According to EN 60947-5-2
10
7
According to EN 60947-5-3
TÜV, UL
see drawing
20
≤ 0.1
≤ 1
< 166,000
< 70,000
20
4
3
e
d
2.5 x 10
--8
1.0 x 10
-7
= switching voltage
e
Combination options for evaluation unit CMS-E-ER
Unit
Design
Read head
mm
kg
°C
CMS-R-AXH/-SC
°C
CMS-R-BXI/-SC
M25
CMS-R-CXC/-SC
V AC/DC
mA
M30
V AC
CMS-R-EXM/-SC
mA
A
mA
VA
CMS-RH-AYA-...L
A gG
CMS-RH-BYB-...L
A
2) Old conductor coloring in brackets.
3) There must be no ferromagnetic material in the vicinity of the read head or the actuator.
All data refer to the frontal approach direction and a center offset of m = 0.
4) The minimum switching distance S
less than this, the evaluation unit changes to the fault state.
V
ms
A
years
Suitable for 35-mm mounting rail acc. to DIN EN 60715 TH35
Figure 1: Dimension drawing for evaluation unit CMS-E-ER
7
Assured
Circuit
switch-on
diagram not
Actuator
distance s
actuated
2)
[mm]
CMS-M-AC
6
4)
CMS-M-BD
3
BN
1
WH
2
BU (GN)
3
CMS-M-CA
6
BK (YE)
4
CMS-M-EF
6
BN +
PK
CMS-MH-AA
10
WH
GY NC
BU
CMS-MH-BB
6
BK -
between read head and actuator is 1 mm. If the distance is
omin
99
Assured
switch-off
distance s
ao
ar
[mm]
3)
31
12
14
17
20
13

Publicidad

Tabla de contenido
loading

Tabla de contenido