USA – Ceiling Limit (Short Term Exposure Limit = 15 minutes)
CO
CO
2
NO
5 ppm
2
Canada 8-hr time weighted average WorkSafe BC OHS Guidelines Part 5.1 and Ontario Work¬places Reg
833
CO
25 ppm
CO
5000 ppm
2
NO
3 ppm (Reg 833)
2
Canada STEL (15 minutes Reg 833/1 hour WSBC) WorkSafe BC OHS Guidelines Part 5.1 and Ontario Work-
places Reg 833
CO
100 ppm
CO
15,000 ppm (WSCB)
2
30,000 ppm (Reg 833)
NO
1.0 ppm (WorkSafeBC)
2
5.0 ppm (Reg 833)
Note: Installation of this appliance at altitudes above 2000 ft (610 m) shall be in accordance with local codes, or in the ab-
sence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or National Standard of Canada, Natural Gas and
Propane Installation Code, CSA B149.1.
IMPORTANT SAFETY INFORMATION
1. If the heater is being used in the presence of others, be sure to inform them of the proper safety precautions,
operating procedures and the hazards involved. Some people are more affected by carbon monoxide than
others. These are pregnant women, people with heart or lung disease or anemia, those under the influence
of alcohol or at high altitudes.
2. Use 20 lb. LP cylinders only.
3. Check the heater thoroughly for damage before each use. DO NOT operate a damaged heater.
4. DO NOT modify this heater or operate a heater that has been modified from it's original state. Modifying
this heater will void your warranty.
5. Keep children and animals away from heater.
6. Always set heater on a stable, level surface and use the caster locks to prevent movement of the heater.
7. NEVER use heater in occupied dwellings without proper ventilation.
8. Operate in a manner that heater will not be exposed directly to rain or dripping water.
9. Keep heater area free from combustible materials such as gasoline, paint thinners and other flammable
vapors and liquids. Dust is combustible. Do not use heater in areas of high dust concentration.
10. ALWAYS maintain proper distance from combustibles.
11. NEVER leave heater unattended.
12. Use heater in accordance with all local codes and with CSA 5.90 U.S. (5th Ed.) Infrared Patio Heater.
13. In the absence of local codes, refer to the Standard for the Storage and Handling of Liquefied Petroleum
Gases, ANSI/NFPA 58 and the Natural Gas and Propane Installation Code, CSA B149.1.
14. This heater is not for use on finished floors.
10
GENERAL SAFETY INFORMATION
Propane Heater Manual