DISPLAY DATA
DESCRIPTION
dEF
no / Si
Select the item Si to load the default values
riP.E
Light on at rest on the outer side
SPEn
- outer lights off
vErd
- green light on fixed
roSS
- red light on fixed
riP.U
Light on at rest on the inner side
SPEn
- outer lights off
vErd
- green light on fixed
roSS
- red light on fixed
AUt.E
no / Si
Automatic starting up on the outer side
AUt.U
no / Si
Automatic starting up on the inner side
trAn
Si / no
Calculation of the transiting vehicles
Po.S.P
n.C / n.A
Polarity of the sensor of presence (Normally closed n.C / Normally open n.A)
t.PrE
0.0" ÷ 19.9"
Length of time necessary to signal the presence
t.PAS
0.0" ÷ 19.9"
Time necessary to signal the transit
PrEC
Direction with right of way
no
- green is given to the first vehicle on the sensor of presence
USC
- green is always given to the outgoing vehicle
inGr
- green is always given to the incoming vehicle
t.Lro
no ÷ 99.5"
Time of pre-flashing of the red
t.vEr
0.0" ÷ 99.5" Time of green
t.LvE
no ÷ 99.5"
Time of flashing of the green
t.roS
0.0" ÷ 99.5" Minimum time of the red
i.SCA
Si / no
Enabling of the warning light of open gate
C.CEn
Mode to send the start control on the control unit of the gate
- a control pulse is given each time recognized the request of starting up of the
Mon
no
- the relay is never started up
- the control is kept active during the pre-flashing phase of the red and until given
biSt
i.ALL
Enabling of the alarm input
no
- the input is disabled (it is no necessary to jumper)
- as soon as the input is active the situation is of emergency; stopped the alarm
biSt
- once recognized the state of alarm, the control unit does not get back to its
Mon
CAP
0 ÷ 9999
Car park capacity
diSP
Display state
inPU
- the control panel is always displayed
- generally the control panel is displayed, but when transiting a vehicle the
trAn
Cont
- the number of vehicles inside the car park is constantly displayed
n.int
0 ÷ 9999
Number of vehicles inside the car park
FinE
End of programming mode
no
- other changes to be made, don't exit the programming mode
Si
- changes finished: end of programming, the control panel is displayed
City5 FUNCTION TABLE
phase in any way
the green light in a way
the control unit gets back to its normal working
normal working: it is necessary to disconnect
number of vehicles inside the car park is displayed for 2 seconds
32
MEMO
DEFAULT
DATA
no
SPEn
SPEn
no
no
Si
n.C
0.5"
0.1"
no
1.0"
15.0"
2.0"
2.0"
Si
Mon
no
0
inPU
0
no