TYPICAL EMPLOYMENTS
The high flexibility of the control unit City5 makes it suitable to different situations.
For this reason, it is not possible to give a starting standard configuration to be adapted with few adjustments, as each situation may
need particular settings. The following paragraphs show some typical employments using a suitable configuration which can be a
starting point for similar installations. Note: the tabs contain only the most important parameters suitable for that kind of employment.
Employment 1
Gate driven by a control unit not equipped
with output for warning light
Parameter
Value
RIP .E
SPEN
RIP .U
SPEN
AUT.E
AUT.U
TRAN
T.LRO
1.0"
T.VER
15.0"
T.LVE
2.0"
T.ROS
2.0"
I.SCA
C.CEN
MON
At rest, the traffic lights are on fixed on red,
because the state of the gate is unknown.
The pre-flashing time of the red light has to
be set in order to coincide with the opening
time of the gate.
Once started up the phase, the succession
green, flashing green and minimum time of
red have a fixed length, independent from
the state of the gate.
Employment 2
Gate driven by a control unit not equipped
with output for warning light
Parameter
Value
RIP .E
ROSS
RIP .U
ROSS
AUT.E
AUT.U
TRAN
T.LRO
20.0"
T.VER
15.0"
T.LVE
2.0"
T.ROS
20.0"
I.SCA
C.CEN
MON
At rest, the traffic lights are on fixed on red,
because the state of the gate is unknown.
The pre-flashing time of the red light has to
be set in order to coincide with the opening
time of the gate.
Once started up the phase, the succession
green, flashing green and minimum time of
red have a fixed length, independent from
the state of the gate.
NO
NO
SI
SI
NO
NO
NO
NO