7.6 Start-up

Test the operation of the unit by turning the thermostat knob in a clockwise
direction. The compressor must start up within 30 seconds, after which you will hear
a slight hum. The fan will also start up a few minutes after the evaporator starts to
freeze. You can adjust the temperature considering that the lowest temperature can
be obtained by rotating the knob clockwise and the highest temperature, conversely,
by bringing the knob to the position closest to that of the circuit breaker. To stop
unit operation, fully rotate the same knob in a counter clockwise direction. The
thermostat opposes some resistance which must be countered.

7.7 Electrical mains power supply

Connection to the electrical mains can be made for Compact Classic operation.
When using a battery charger, always connect it to the battery and never to the
refrigerator's electronic unit. An even better solution is installing a "Power Pack"
transformer, an optional accessory, which switches automatically from battery power
to electrical power when the latter is connected.
When using a AC/DC (100/240 Vac and 12-24 Vdc) control unit, make sure that:
- the connection is double insulated as in the figure
Figure 11: Detail of double insulated connection
- the earthing cable is longer than the other cables to ensure it will the last to
disconnect if pulled.
- the earthing cable is connected via a screw on the metal structure/s of the
compressor as indicated in the figure in the suitable allocation