9

Technical data

INPUT (DC)
Max. recommended PV
power
Nominal power
Voltage range
MPP range
Full power MPP range
Nominal current
Max. current
Stand-by power
STANDARDS / DIRECTIVES
Protection degree
Safety class
Configurable trip
parameters
Insulation monitoring
Overload behavior
Safety
Anti-islanding
protection
EMC
GENERAL SPECIFICATION
Model name
Max. efficiency
Efficiency EU
Operating temperature -25 ... +70 °C
Storage temperature
Humidity
30
3100 W
P
2750 W
125 ... 540 V
150 ... 450 V
150 ... 450 V
10.0 A
18.0 A
< 0.2 W
IP65
1
Yes
Yes
Current limitation;
power limitation
EN60950-1; EN50178;
IEC62103; IEC62109-1 / -2
DIN VDE 0126-1-1; RD 1663;
RD 661; ENEL G.L. 2010; UTE
15712-1; Synergrid C10/11;
EN 50438; G83/1-1
EN61000-6-2; EN61000-6-3;
EN61000-3-2; EN61000-3-3
SOLIVIA 2.5 EU G3
96.0 %
94.4 %
-25 ... +80 °C
0 ... 98 %
OUTPUT (AC)
Max. power *
Nominal power
Voltage range **
Nominal current
Max. current
Nominal frequency
Frequency range **
Power factor
Total harmonic
distortion (THD)
MECHANICAL DESIGN
Size (L x W x D)
Weight
Cooling
AC connector
DC connector pairs
Communication
interfaces
DC disconnector
Display
* The maximum AC power value indicates the power
an inverter might be able to deliver. However, such a
maximum AC power may not necessarily be achieved.
** AC voltage and frequency range will be programmed
according to the individual country requirements.
Operation and installation manual SOLIVIA 2.5 EU G3
2600 W
2500 W
184 ... 264 V
11.0 A
13.0 A
50 Hz
47.0 ... 52.0 Hz
> 0.99 @ nominal power
< 3 % @ nominal power
410 x 410 x 180 mm
21.5 kg
Convection
Wieland RST25i3S
3 Tyco Solarlok
2 Harting RJ45 / RS485
Integrated
LCD; 3 LEDs