Installation Instructions - Standard Installation
STEP 5 LEVEL UNIT
All models have 4-point leveling. The front is supported
by leveling legs; the rear is supported by adjustable
wheels. Both are accessible from the front of the unit.
• To level the back of the unit, turn the 7/16" hex nut
located above the front wheels. Turn clockwise
to raise or counterclockwise to lower the unit.
• For front leveling, use a 1-1/4" open-end wrench.
• Adjust height of unit to match installation cutout open-
ing 84-1/2" (214.63 cm). The unit should be level and
plumb with cabinetry.
The rear leveling wheels and front leveling legs are
limited to a maximum height adjustment of 1"
(2.54 cm). If the installation requires more than 84-1/2"
(214.63 cm) height, the installer should elevate the unit
on a sheet of plywood or runners. Cabinetry trim could
also be added across the top of the opening to shorten
the opening. If you attempt to raise the unit more than
1" (2.54 cm), you will damage the front leveling legs
and the rear leveling wheels.
STEP 6 SECURE UNIT TO WALL
• The "L" rods can be found in the upper left and right
corners of the unit in the access compartment. Look
through the access compartment to make sure the
rods line up with the anti-tip bracket.
• There are 2 washers and a hair pin cotter per rod.
Remove the washers and hair pin cotter from the end
of the rod.
• Rotate and move
the "L" rod into the
slot in the anti-tip
bracket tab. Once
it is in the slot,
rotate the "L" rod
so the hook portion
is pointing down.
The holes at the
front end of the rod
should be in a vertical position. Do this to both sides.
• Pull out on the end of the rod to make sure it is
secure in the bracket.
• Locate the hole on the rod that is closest to the unit.
A hair pin cotter will be put through this hole to secure
the rod. If this hole appears to be too far away for a
snug fit against the unit, add the washers one at a
time until the pin will fit tightly into the hole.
• Align the straight
section of the pin
with the hole from the
underside of the rod.
Push the pin up until
it snaps into position.
Pliers may be used.
NOTE: The hair pin
cotter must be vertical
when this step is
completed to ensure
the "L" rod is engaged
in the bracket.
• Check the rod for
tightness by pulling forward. If the rod moves, remove
the hair pin cotter and place another washer on the
rod. Reinsert the pin.
• Replace the grille panel.
18
"L" Rod
Wall Bracket
"L" Rod
31-1000416 Rev. 0