3.8.3 Horizontal alignment
Move the measuring units to the 3 o'clock position (fig.
23).
Observe the coupling and feet values live adjustment.
Machine misalignment should be within the
manufacturer's specified tolerances. In case such
tolerances are missing, table 1 can again be used as a
general recommendation.
a) If the measured coupling values are within the
tolerances, no sideways adjustment is necessary.
b) If the measured coupling values are higher than
the acceptable tolerances check the recommended
correction on the feet.
SKF TKSA 20
Fig. 23. The 3 o'clock position
Fig. 24. Horizontal alignment
19