e) Assure that external extensive vibrations do not influence the measurement.
f) Assure that radio communications (like walkie-talkies) do not influence the
measurement.

5.2.5 Incorrect measuring results

a) Assure you face the Stationary machine from behind the Movable machine.
b) Check the attachment of fixtures and measuring units.
c) S-cable to S-unit and M-cable to M-unit?
d) S-unit on Stationary and M-unit on Movable machine?
e) Assure right position before confirmation of measurements.

5.2.6 Measurement results cannot be repeated

a) Check if there is a soft foot condition.
b) Check if there are any loose mechanical parts, play in bearing or movements in the
machinery.
c) Check the status of foundation, base plate, bolts and existing shims

6. Maintenance

6.1 Handle with care

The measuring units are equipped with sensitive electronic and optical parts.
Handle them with care.

6.2 Cleanliness

For best function the system should be kept clean. The optics near the laser and
detector should be free of finger prints. If necessary clean with cotton cloth.

6.3 Batteries of the display unit

The display unit is powered by two LR14 (C) batteries. Most LR14 (C) batteries can
be used, but Alkaline batteries have the longest life. If not using the system for a
long period, remove the batteries from the display unit. Flat batteries will be
indicated by the battery signal on the display.

6.4 Replacement of measuring units or display unit

Both measuring units are calibrated in pairs and hence they must be replaced as a
pair.