Prior To Commissioning - diversey TASKI swingo 1660 Instrucciones Originales De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Prior to commissioning

Relocation drive
• Switch on the machine (key switch).
The display lights up briefly.
The battery level indicator notifies
you that the machine is ready for op
eration. (In case of malfunctions,
please see page 14).
• Take the driving handle and arrange
the height of the driving switches in
such a way that you can work easily
with them.
• By gently pushing the driving switch
into the direction of movement, the
machine is set into motion. If you let
go of the driving switch, the machine
will stop.
Brush installation
Before inserting, please check:
• that the brush does not fall below the red marking (bristles)
or 1cm of bristle length.
• the pad for wear and cleanliness before use.
Attention:
Do not use brushes which have reached
their wear limit. The wear limit is indicated
by the length of the red bristle. Do not use
worn or contaminated pads. Use original
TASKI brushes only. Failure to observe
these instructions may result in inade-
quate cleaning results or even floor dam-
age.
• Position the brush under the brush unit.
• Switch the machine on.
The indicator elements lights up briefly.
• Unlock the foot pedal and lower the
tool slowly.
While lowering the brush drive will
slowly start to pulse. In this way the
tool is centered and engaged.
The brush drive display lights up.
Notice:
When the brush is down, gently moving
the machine back and forth can make the
clutch easier to engage.
8
Squeegee assembly
• The machine must be switched off (main switch).
1
-
1
2
2
Filling the fresh water tank
Attention:
Max. permissible water temperature
60 °C/140 °F.
Diversey recommends using cold water
since hot water will adjust to the floor tem-
perature as soon as it is in contact with the
floor. Thus there are no advantages to us-
ing hot water.
• The machine must be switched off (main switch).
• Open the tank cover until the support engages in the tank
wall.
• Fill the fresh water tank with water.
Maximum filling level (page 5).
• Tip the tank cover back into its original position and press
it down until it locks.
Dosing
Attention:
Wear gloves, goggles and appropriate
(protective) working clothes when han-
dling chemical products!
Notice:
Use chemical products recommended by
Diversey only and always observe the
product information.
Caution:
Using unsuitable products (e.g. products
containing chlorine, acids or solvents) may
cause harm to health and severe damage
to the machine.
• Position the suction nozzle (2) below
the suction nozzle holder (1).
• Press the foot pedal down until the
suction nozzle holder engages.
• Attach the suction hose to the con-
nector.
• Put your hand into the opening be-
tween tank cover and tank.
Palms upwards.
• Remove the dosage aid.

Publicidad

Tabla de contenido
loading

Tabla de contenido