• Carefully tip the tank backwards.
Now the battery can be maintained
according to the manufacturer's noti-
fication.
Warning:
After maintenance, carefully bring the tank back to
its initial position and screw in the screw.
Prior to commissioning
Brush installation
Before inserting, please check:
• that the brush does not fall below the red marking (bristles)
or 1cm of bristle length.
• the pad for wear and cleanliness before use.
Caution:
Do not use brushes which have reached their wear
limit. The wear limit is indicated by the length of the
red bristle. Do not use worn or contaminated pads.
Use original TASKI brushes only.
Failure to observe these instructions may result in inad-
equate cleaning results or even floor damage.
• Position the tools under the tool unit.
• Switch the machine on.
• To do this, press the main switch but-
ton (ON/OFF) for 3 seconds.
The display lights up briefly.
• Unlock the foot pedal and lower the
tool slowly.
• Briefly press the operating lever.
In this way the tool is centered and engaged.
Notice:
When the brush is down, gently moving the ma-
chine back and forth can make the clutch easier to
engage.
Suction nozzle assembly
• The machine must be switched off (main switch).
• Position the suction nozzle (2) below
the squeegee holder (1).
1
1
2
2
• Press the foot pedal down until the
squeegee holder engages.
• Attach the suction hose to the con-
nector.
Filling the fresh water tank
Notice:
Max. permissible water temperature 60 °C/140 °F.
Diversey recommends using cold water, as hot wa-
ter will adjust to the ground temperature as soon as
it comes into contact with the ground. Thus there
are no advantages to using hot water.
• The machine must be switched off (main switch).
• Open the tank lid.
• Fill the fresh water tank with water.
Dosing:
Warning:
Wear gloves, goggles and appropriate (protective)
working clothes when handling chemical products!
Danger:
Use chemical products recommended by Diversey
only and always observe the product information.
Using unsuitable products (e.g. products containing
chlorine, acids or solvents) may cause harm to health
and severe damage to the machine.
Notice:
For a precise dosage, use the scale in the dosage
cup.
- The filling level mark on the tank corresponds to the
mark in the dosage cup. The type of machine is also
noted in the dosage cup!
Dosing examples:
Information on the package
of the product
0.25%
25 ml for 10l of
water
0.5%
50ml for 10l of
water
• Fill the dosing cup with a suitable product and pour the con-
tent into the fresh water tank. Repeat the procedure until
the required dosing is reached.
• When dosing is finished, the dosing cup will remain in the
tank.
Tank capacity Product volume
per tank filling
22l
50ml = 0.05l
22l
100ml = 0.1l
7