BONAIRE WINDOW COOLER
Installation
Purge Pump Installation
1. Disconnect electrical power to the cooler.
2. Remove the Rear filter panel (see
Maintenance section for detail).
3. Remove & retain the 2 pump receptacle
cover screws and remove the cover.
1
2
4. Locate the purge pump plug and gently pull
the plug out until the plug is accessible.
Purge pump
plug
5.
Position the purge pump in the base of the
cooler.
Purge
pump
6.
Route the purge pump cable and plug the
purge pump into the available electrical plug.
Ensure there is a "drip loop" in the purge
pump cable (see image below).
Main
Pump
Purge
cable
Pump
cable
Purge
pump
7. Push the plug back in to the opening
and replace the pump receptacle cover
and refit the screws.
8. Route the purge pump hose to the
overflow pipe. (Remove the bleed hose
from the overflow pipe)
9. Refit the Rear filter panel.
Note loop in cable
of Purge pump
Purge
Pump hose
Page | 16