Maintenance
General
Filter Pads
Visually check Filtercool pad for damage or blockage. Gently hose down pad from both sides to remove
any build up of salts, dust and pollen. In dusty areas more regular cleaning is recommended. Check the
water distributor, making sure it is clear and free from blockage. Failure to do so may lead to uneven
water distribution and therefore less efficient operation.
Water Tank
It is important to keep the water tank clean and free from sediment and algae growth. Using a small soft
bristle brush, brush all surfaces in the tank while it is full of water (DO NOT FORGET THE PUMP
STRAINER). Turn off the water inlet to the unit (an isolation valve should be fitted to the water inlet before
the float valve or at the water supply faucet). Drain the tank by undoing the external overflow fitting lock
nut and removing the overflow fitting. After refilling, it may be necessary to repeat this procedure if the
tank is very dirty.
Water Distributor
Check the water distribution system for blockage. Check the delivery tube for kinks or holes.
Note: Water supply line to float valve must be flushed before connecting.
Water Level / Float Valve
The water level should be set at nominal ¾" (19mm) below height of stand pipe lip. The float valve is a
mechanical type and is factory set. If it requires adjustment keep bends tight. If the valve is leaking, it may
require replacement.
Note: Water supply line to float valve must be flushed before connecting.
Note: Some discharge from the overflow may be experienced after shut down due to water
draining back from the Filtercool filter pad. This is normal.
Motor and Fan
Check that the fan spins freely and that there is no build up on the blades. Check the motor for corrosion
and spray with an anti-corrosive agent if necessary.