ENGLISH
6. USB 5Vdc output: this is NOT a data connector, it's only a 5Vdc/350mA output that can be used to
supply power to future accessories.
7. OMEGA CLAMP BASE: base with fixing points for the omega clamp + safety cable, see previous
chapter "overhead rigging"
8. BEAM ANGLE ADJUSTMENT: you can adjust the beam angle seamlessly between 12° and 16° by
simply turning the lens.
MAIN MENU:
To select any of the functions, press the [MODE] button to enter the setup menu.
Use the ▼/▲ buttons to browse the menu.
Select a function with the [ENTER] button.
Use the ▼/▲ buttons to change the mode.
Once the required mode is selected, press the [ENTER] button to select.
Press the [MODE] button for about 2 seconds to store the setting and to return to running mode. If you
don't do this, the setting will not be stored and after some time, the fixture will return to the previous
running mode.
DMX Address
Used to set the starting address in a DMX setup.
Press the [MODE] button and use the ▼/▲ buttons until
[DMX Addr] is shown on the display.
Press the [ENTER] button to start editing.
Use the ▼/▲ buttons to change the DMX512 address.
Once the correct address shows on the display, press the
[ENTER] button to confirm.
Press the [MODE] button for about 2 seconds to store the
setting and to return to running mode.
Channel mode
Used to set the desired channel setup mode.
Press the [MODE] button and use the ▼/▲ buttons until
[Ch. Mode] is shown on the display.
Press the [ENTER] button to start editing.
Use the ▼/▲ buttons to choose 5MSL, 11 or 14ch mode.
Once the desired channel setup mode shows on the
display, press the [ENTER] button to confirm.
Press the [MODE] button for about 2 seconds to store the
setting and to return to running mode.
Show Mode
Used to choose the Show mode when used in standalone
or master/slave mode.
Press the [MODE] button and use the ▼/▲ buttons until
[ShowMode] is showing on the display.
Press the [ENTER] button to start editing.
Use the ▼/▲ buttons to select one of the available shows:
[Floor]: Fixture is placed on the floor. [PAN/TILT]
movements are not limited.
[Ceiling]: Fixture is fixed on the ceiling. [TILT]
movements are limited to ±60°.
[Stage FL]: Fixture is placed on a stage, in front of the audience. The spot is always projecting
towards the audience's direction; i.e. in front of the stage. [PAN] movement angle (left to right to left):
160°. [TILT] movement angle: 90° (60° above horizon; 30° below horizon.)
[Stage CE]: Fixture is fixed upside-down on the ceiling of a stage. The spot is mainly projecting
towards the audience in front of the stage. [PAN] movement angle (left to right to left):160°. [TILT]
movement angle: 90° (vertically, front 75°; back 15°)
Once the right mode is shown on the display, press the [ENTER] button to confirm.
Press the [MODE] button for about 2 seconds to store the setting and to return to running mode.
BRITEQ
®
4/74
USER MANUAL