Komet Vacuboy Instrucciones De Operación página 50

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation and Putting into Operation
SEAL button
To set the sealing time between 0.5 and 9.9 seconds,
increment 0.1 second:
press the SEAL button when the cover is open
-
-
change the sealing time by pressing the
Important!
Limitation for sealing time
The maximum sealing time is fixed ex works according to the type
of machine and cannot be exceeded.
GAS ON/OFF button
To set the desired gas flush time
(Gassing time is continuously adjustable between 0.5
seconds and 10 seconds)
-
press the GAS ON/OFF button when the cover is open
-
change the gassing time by pressing the
Operating Instructions- Translation
or
buttons
or
buttons
LED GAS ON/OFF
Press button to switch on/off chamber gassing.
The LED is illuminated when gassing is switched on.
Danger!
During gas flush operations, only use nitrogen N
CO
or an N
-CO
mix.
2
2
2
Explosion hazard! Under no circumstances use oxygen O
explosive and combustible gases for gas flush operations.
Observe the regulations when handling gas bottles and also
observe the operating instructions for the bottle pressure reducer.
Note!
Switch off the gas supply (shut off the bottle valve on the gas bottle
and the shut-off valve on the bottle pressure reducer), if you are
working without gassing or the machine is not in operation.
Note!
Using the bottle pressure reducer set the working pressure to a
maximum of 1.5 bar.
Important!
Gas flushing is switched off when switching the master switch to 1.
If you wish to work with gas flush, press the GAS ON/OFF button.
19 04 249 - 01.01.2012
or carbon dioxide
2
or other
2
Eng - 15 /32