Oil Inspection And Oil Change; Replacing The Pneumatic Spring - Komet Vacuboy Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance and Fault Repair
8.4

Oil inspection and oil change

Danger!
Electric shock possible!
Pull out the main power plug before starting work!
Caution!
Handle and dispose of the used oil and the oil filter in accordance
with the valid conditions.
Note!
If the machine was in operation, wait for about 15 minutes before
checking the oil (foam reduction).
If the oil is not gold-yellow but white or dark an oil change must be
carried out.
If the oil level is below the MIN mark indicated on the oil inspection
glass, the oil needs to be topped up.
Oil type see chapter "Technical Data".
When changing the oil, the pump must be operationally warm, switched off and
ventilated to atmospheric pressure (no more vacuum in the chamber).
Vacuboy, PlusVac 20, PlusVac 80
Accessible through lifting up the casing:
-
Remove the insertion plates from the
chamber.
Secure the cover with the cover down
-
holder.
-
Vacuboy, PlusVac 20: Open the
casing with removing the two screws on
the backside of the machine and lift up
the casing from the backside.
-
PlusVac 80: Open the casing with
removing the two screws on the front
side of the machine and lift up the
casing from the front side.
Operating Instructions- Translation
PlusVac 21
Accessible through the open
backside.
1 Oil inspection glass
2
2 Oil filler screw
3 Oil drain screw
Remove the oil filler screw 2.
Let the used oil out through the oil drain screw 3 into
1
a suitable container.
Screw back down the oil drain screw.
Refill the fresh oil until the MAX mark has been
reached on the oil inspection glass 1.
Close up the oil inlet using the oil filler screw 2.
3
Figure valid for pump 40 m
Other types of pump, see cover page 3
Important for Vacuboy, PlusVac 20 and PlusVac 80 !
Do not squeeze the tubes and cables when closing the casing.
8.5

Replacing the pneumatic spring

Please contact our customer service department or ask for our replacement
instructions!
19 04 249 - 01.01.2012
3
/h.
Eng - 27 /32

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Plusvac 20Plusvac 80Plusvac 21

Tabla de contenido