Technical Data
Total connected load electric: 25 VA
Nozzle Table Wok Burner
Gas
Pressure
Nozzle, full burn, outer
Nozzle, low burn, outer
Nozzle, full burn, inner
Nozzle, low burn, inner
Air gap adjustment, outer 0 mm
Total connected load
Total consumption
Nozzle Table Large Burner
Gas
Pressure
Nozzle, full burn, outer
Nozzle, low burn, outer
Nozzle, full burn, inner
Nozzle, low burn, inner
Air gap adjustment, outer 0 mm
Total connected load
Total consumption
Nozzle Table Small Burner
Gas
Pressure
Nozzle, full burn, outer
Nozzle, low burn, outer
Nozzle, full burn, inner
Nozzle, low burn, inner
Air gap adjustment, outer 0 mm
Total connected load
Total consumption
6
Natural Gas
LPG (Propane)
Type N
Type X
6" water col-
10" water col-
umn (1.5 kPa)
umn (2.5 kPa)
173
110 A
75
56
60
42
48
34
2 mm
59 700 BTU
58 000 BTU
(17.5 kW)
(17 kW)
1.67 m³/h
1160 g/h
Natural Gas
LPG (Propane)
Type N
Type X
6" water col-
10" water col-
umn (1.5 kPa)
umn (2.5 kPa)
150
105
65
45
40
29
42
28
2 mm
59 700 BTU
58 000 BTU
(17.5 kW)
(17 kW)
1.67 m³/h
1160 g/h
Natural Gas
LPG (Propane)
Type N
Type X
6" water col-
10" water col-
umn (1.5 kPa)
umn (2.5 kPa)
97
68
48
34
40
29
42
28
open at MAX
59 7000 BTU
58 000 BTU
(17.5 kW)
(17 kW)
1.67 m³/h
1160 g/h
Installation Procedure
Prepare Installation Space
Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
Observe minimum distance between appliance
underside and furniture parts of
When installing multiple Vario appliances:
account space requirement for VV 200 connection
strip between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
(40 mm).
Install Appliance
,
WARNING:
Before you plug in an electrical cord
or turn on power supply, make sure all controls
are in the OFF position.
Air intake from above. No intermediate shelf required.
Stovetop clamping range: 30 - 50 mm.
1
Cut out an opening in the countertop according
to the installation drawing. Check the minimum
clearance from the rear wall and the sides of
kitchen units. Seal the edges of the cut-out.
2
Turn the clamp fasteners to the side. Place the
gas hotplate into the cut-out and align it evenly.
3
Tighten all clamp fasteners evenly. Check that the
whole frame lies evenly flat on the countertop.
4
Fit the burner rings, burner lids and pan supports.
5
Connect the appliance to the gas and electricity
supply. The appliance is not operable without
power supply.
6
Test the appliance for correct functioning. There
might be an air pocket in the gas supply line if the
appliance turns off and the indicator lights flash.
Turn all control knobs to 0 and ignite the burner
again.
3
/
" (10 mm).
8
Take into
/
"
9
16