NSS WRANGLER 2730 DB Instrucciones Originales página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Flooded (wet) batteries can be easily identified by the
removable cell caps. Removing the caps allows
inspection of the liquid electrolyte (sulfuric acid) level in
each cell.
AGM (Absorbed Glass Mat) batteries are sealed,
maintenance free batteries. The do not have cell caps
intended for removal. Look for "AGM" printed on the
tops or sides of the batteries.
Gel (gelled electrolyte) batteries are also sealed,
maintenance free batteries. They do not have cell caps
intended for removal. Look for "GEL" printed on the
tops or sides of the batteries.
Battery Charger Indicator LED's
Your battery charger is equipped with LEDs that
indicate the following:
 Battery Type Setting. Either of these two LEDs will
be illuminated, anytime the charger is plugged in, to
signal which type(s) of batteries the charger is
configured to charge. The two options available are:
 Wet / AGM: When this LED is illuminated, the
charger is configured to charge either flooded
(wet), or AGM batteries.
 Gel Cell. When this LED is illuminated, the
charger is configured to charge Gel batteries
ONLY. EXCEPTION: Crown and Trojan AGMs
are to be charged with the Gel setting.
 State of Charge Indicators. Four additional LEDs
provide information about the charge level of the
batteries during charging.
o 30%, 60%, 90% and 100%.
 Fault Indications. During charging, the charger
provides feedback about the charge process and any
problems detected. It will provide feedback and
signal the type of problem by flashing LEDs as
described below:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wrangler 3330 db

Tabla de contenido