Cooling And Exhaust Air; Air-Conditioning Unit And Condensate Pump - KBL megaSun Serie Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cooling and exhaust air

COOLING PRINCIPLE
Cooling of the tanning unit: The fan sucks in the
ambient air for cooling through the upper and lower
filter pads. It discharges the warm air via the exhaust
air duct.
Cooling of the body: A fan at the foot end sucks
in ambient air (systems without air-conditioning unit)
or cooled air (systems with air-conditioning unit) and
blows it into the tanning space of the solarium. A
spoiler at the canopy pane leads this air to the face
area.
Cooling of the bed pane: The air that is cooled down
in the air-conditioning unit is blown towards the foot
end between the bed pane and the ducting pane and
then led further into the tanning space.
MAINTENANCE OF ThE EXhAUST AND AIR-
CONDITIONING UNIT
A clean and trouble-free exhaust-air unit prevents
the tanning system from overheating. The maximum
exhaust-air hose length of 6 m must not be exceeded
unless there is an auxiliary fan installed.
Procedure
Check the air-conditioning unit and the
1
condensate pump as described in the
following chapter.
The filter pads in the bed section and
2
in the canopy must be clean.
Check the exhaust-air hose for kinks
and damages; also test the function of
3
the auxiliary fan in the case of excessive
hose lengths.
Sufficient airing and ventilation of
4
the tanning studio must always be
ensured.
Check the correct positioning of the
5
ducting pane in order to ensure the
proper cooling of the bed pane.
Air-conditioning unit and
condensate pump
MAINTENANCE OF ThE AIR-CONDITIONING UNIT
Check the heat exchangers of the air-conditioning
unit for dirt accumulation with each tube replacement.
Soiled heat exchangers reduce the performance of
the air-conditioner.
Open the front cover and vacuum-clean the heat
exchangers, if necessary.
Check the air hose each time you change tubes. If
it is defective, replace it immediately.
Figure 39.1: Air-conditioning unit and condensate pump
Fig.
39.1
37.4
37.5
13
Condensate hose
14
Condensate pump
15
Condensate tray
Position of air hose and fan
16
(rear right-hand side)