Connections

Connecting the mains voltage

Live components
Risk of fatal injury due to electric shock
when touching live parts.
Disconnect from mains according to DIN
VDE 0105.
Both the power supply and the related connection
work must comply with national standards, e.g. those
set up by VDE in Germany. The connection must only
be performed by qualified expert staff.
The connection to the 400 V mains must be protected
by fuses. Their specifications are listed in the chapter
"Technical data".
A residual current-operated circuit breaker (RCD)
must always be used. KBL-Solarien AG recommends
the following type: KBL 3200 0770 00 (type ABB F 374
63/0.03A). Should the operation of the tanning unit
cause any interference in the power supply network,
e.g. with ripple-control systems (TRA), consult your
power supply company regarding the installation of
corresponding blocking elements (audio frequency
suppressor).
Figure 8.1
mains connection
400V / 3N / 50Hz coupling box with fuses
and residual current operated circuit
breaker (RCD) of type ABB
63/0,03A (KBL 3200077000)
PE L1 L2 L3 N
8
M a n u a l d e u s u a r i o | megaSun 4000 / 4500
DANGER!
F 374
Connecting an external audio
source
When connecting an external audio source, pay
attention to the correct polarity.
Figure 8.2
Wiring on the audio equipment's side
R-
EXTERNAL AUDIO SIGNAL 100 V (OPTIONAL
FEATURE)
A transformer (KBL item no.: 9100 0170 00) is
required for the transmission of the audio signal if a
100 V audio system is connected.
The connection must be carried out by trained service
staff.
R+ L-
L+