Operation
5.1
Comply with all safety instructions and instructions for use.
WARNING
Chemicals hazard Incorrect use can lead to injury.
▶ Prior to use, read and comply with the safety data sheet for the product, the instructions on the packaging
and the instructions for use of the foil pack.
5.2
Inserting the battery
▶ Push the battery into the dispenser from the rear until it engages with an audible click.
5.3
Removing the battery
▶ Remove the battery.
5.4
Inserting the foil pack holder and foil pack
CAUTION
Trap hazard Hands can be trapped if care is not exercised when swiveling the foil pack holder closed.
▶ Keep your hands clear of the cradle area when swiveling the foil pack holder into position.
CAUTION
Risk of injury Chemicals hazard.
▶ Check the foil pack holder for damage and soiling. Both pistons must move smoothly and easily in both
directions over the full length of their travel in the foil pack holder. Replace the foil pack holder if it is
damaged and/or badly soiled.
1. Press the release button.
2. Pull the piston rods back as far as they will go.
3. Fit the foil pack holder and swivel it upwards.
4. Screw the static mixer (mixing nozzle) onto the foil pack.
5. Push the foil pack into the foil pack holder.
6. Swivel the foil pack holder into the dispenser.
5.5
Inserting the cartridge
1. Press the release button.
2. Pull the piston rods back as far as they will go.
3. Fit the cartridge.
4. Screw the static mixer (mixing nozzle) onto the foil pack.
5. Swivel the cartridge into the dispenser.
5.6
Discarding initially dispensed mortar
WARNING
Risk of injury Chemicals hazard.
▶ Never point the dispenser toward yourself or other persons. Incorrect use can lead to injury.
WARNING
Risk of injury Chemicals hazard.
▶ Begin dispensing mortar only after the mixing nozzle has been screwed on. Incorrect use can lead to
injury.
Discard the initially dispensed volume of mortar every time the static mixer (mixing nozzle) is changed.
The initially dispensed mortar is not suitable for use.