14 Additional Datasheet - Vaillant VAM 3-050 W2N Manual De Instalación

Ocultar thumbs Ver también para VAM 3-050 W2N:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Combination of indoor units
Outdoor unit
Unit 1
25
VAF 3-060 W2NO
25
25
VAF 3-085 W4NO
25
Combination of indoor units
Outdoor unit
Unit 1
25
VAF 3-060 W2NO
25
25
VAF 3-085 W4NO
25
Combination of indoor units
Outdoor unit
Unit 1
25
VAF 3-060 W2NO
25
25
VAF 3-085 W4NO
25
Table 13.3 Capacity by combinations.

14 Additional datasheet

Outdoor unit
Indoor Unit 1
Indoor Unit 2
Indoor Unit 3
Indoor Unit 4
Cooling
Outdoor Sound Power Level
Heating
Indoor
Sound Power Level Cooling
Cooling
Outdoor Rated Airflow
Heating
Indoor
Rated Airflow
Cooling
Indoor
Rated Airflow
Heating
Refrigerant type
GWP
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to
global warming than a refrigerant with higher GWP, if leaked to the atmosphere.This appliance contains a refrigerant fluid with a
GWP Fixed Text
GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming
would be 1975 times higher than 1 kg of C02, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or
disassemble the product yourself and always ask a professional.
Capacity control
Cooling function included
Heating function included
Average climate included
Cold season included
Warm season included
Energy label
Pdesign
SEER
Annual energy consumption
VAI3-MWN-I_EN - 09/14 - Vaillant
Unit 2
Unit 3
Unit 4
25
35
25
35
25
25
35
Unit 2
Unit 3
Unit 4
25
35
25
35
25
25
35
Unit 2
Unit 3
Unit 4
25
35
25
35
25
25
35
Nom.
outdoor 7(6) / indoor 20 (max 15)
Nom.
Heating/Average
Design load
Seasonal efficiency
Pdesignh
SCOP/A
5,6 kw
3,8
5,6 kw
3,8
9,3 kw
3,8
9,3 kw
3,8
Heating/Warmer
Design load
Seasonal efficiency
Pdesignh
SCOP/W
/
/
/
/
/
/
/
/
Design load
Seasonal efficiency
Pdesignh
SCOP/C
/
/
/
/
/
/
/
/
VAF 3-050 W2NO*
VAI 3-025 WMNI
VAI 3-025 WMNI
/
/
63
N.A.**
52
m³/min
3200
m³/min
3200
m³/min
500
m³/min
500
R410A
1975
Variable
YES
YES
YES
NO
NO
YES
kW
5,00
5,60
kWh
313
TECHNICAL DATA
Annual electricity
consumption
QHE
1776 kwh/a
1776 kwh/a
2616 kwh/a
2616 kwh/a
Annual electricity
consumption
QHE
/
/
/
/
Heating/Colder
Annual electricity
consumption
QHE
/
/
/
/
VAF 3-085 W3NO*
VAF 3-085 W4NO
VAI 3-020 WMNI*
VAI 3-025 WMNI
VAI 3-035 WMNI
/
68
N.A.**
51 / 52 / 56
3800
3800
450 / 500 / 550
450 / 500 / 550
R410A
1975
Variable
YES
YES
YES
NO
NO
YES
8,00
5,10
549
EN
Energy efficiency
class
A
A
A
A
Energy efficiency
class
/
/
/
/
Energy efficiency
class
/
/
/
/
VAI 3-020 WMNI*
VAI 3-020 WMNI*
VAI 3-020 WMNI*
VAI 3-020 WMNI*
68
N.A.**
51
4000
4000
500
500
R410A
1975
Variable
YES
YES
YES
NO
NO
YES
8,00
5,10
549
- 23 -