Stove Turned Off; Re-Ignition Of The Stove; 10 Alarms; Power Supply Failure (Black Out) - Bio Bronpi Aire Serie Instrucciones De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para Aire Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

9.5.7

STOVE TURNED OFF

When the stove is turned off, the display shows the following
information (see drawing D64):
9.5.8

RE-IGNITION OF THE STOVE

When the stove is turned off it would not be possible to restart it
up until some safety time goes by and the stove is cold enough. If
you try to start-up the stove, the display will show up the following
information (see drawing D65):

10 ALARMS

In case of an anomaly during the operation, the electronics of the
stove intervene and highlight the irregularities that have ocurred in
the different working phases, depending on the type of fault.
Every alarm situation blocks the stove. By pressing button 4 we can
unblock it. Once the stove has reached the appropriate cooling
temperature, the user can restart it up.
10.1

POWER SUPPLY FAILURE (BLACK OUT)

In the event that power supply is cut for less than 30 seconds, the
stove will restart and continue with its normal working state.
In the event that power supply is cut for greater than 30 seconds,
when power is restored, the stove, as a safety measure, goes
straight to the Final Cleaning stage until the stove temperature
reaches the appropriate cooling temperature.Once the final cleaning
has finished, the stove will turn off until the user ignite it again (see
drawing D66).
10.2

SMOKE TEMPERATURE PROBE ALARM

This alarm goes off when the probe in charge of detecting the
exhaust stack temperature is disconnected or it breaks. During the
alarm status, the stove will be in the turn-off stage (see drawing
D67).
10.3

SMOKE TEMPERATURE EXCESS ALARM

It goes off when the probe detects a smoke temperature higher than
270°C. Therefore the display shows the following message (see
drawing D68):
During the alarm state, the stove will be in the turn-off stage.
10.4

DAMAGED SMOKE EXTRACTION FAN ALARM

It goes off when the smoke extraction fan breaks down. If this
happens, the stove does stop and the display will show up the
following alarm (see drawing D69). Right after, the turn-off stage will
be immediately activated.
To deactivate the alarm press button 4 and the stove will come to the
normal state after doing the final cleaning.
10.5

IGNITION FAILURE ALARM

In case of ignition failure (after 20 minutes at least) the display will
show up an alarm as follows (see drawing D70).
To deactivate the alarm press button 4 and the stove will come to
the normal state after doing the final cleaning.
10.6

SWITCHING-OFF FAILURE DURING WORKING PHASE

If the flame extinguishes during the working stage and the smoke
temperature goes lower than the minimum working threshold,
the alarm does go off and the turn-off stage will be immediately
activated (see drawing 71).
To deactivate the alarm press button 4 and the thermo-stove will
come to the normal state after doing the final cleaning.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
21:10
22 ºC
OFF
STAND-BY
COOLING
12:42
22 ºC
FINAL
CLEANING
ALARM 2
SMOKE
SENSOR
ALARM 3
ALARM
SMOKE TEMP.
ALARM 4
ASPIRATION
FAILURE
ALARM 5
IGNITION
FAILURE
ALARM 6
NO PELLET
37
P-1
D64
D65
P-3
D66
D67
D68
D69
D70
D71
AIR SERIES