EN
MOBILE AIR CONDITIONER/
DEHUMIDIFIER
Many thanks for choosing this EUROM equipment: you have
chosen an excellent device that you will be able to enjoy for many
years to come!
In order to ensure it works as efficiently as possible, we advise
you to read these instructions carefully before using; the leaflet
contains important safety information, recommendations etc. and
will help you get the very best from your equipment!
We recommend that you keep the instruction booklet and the pac-
kaging in a safe place; the leaflet can then be used as reference
material and the packaging can be used to store your equipment
at the end of the season.
Finally, we hope your air conditioner / dehumidifier perfectly meets
your requirements!
TECHNICAL SPECIFICATIONS
Cooling capacity
Max. power usage
Air displacement max.
Connected power
Sound power level
Cooling fluid
Class of insulation
Fan settings
Operating temperature
Waste pipe
Ø 150 mm x 1500 mm
Net weight
Dimensions (l x b x h)
SAFETY INSTRUCTIONS
General Safety
• This unit is exclusively intended for household use.
• Always ensure (even during transport!) that the unit remains
upright. If the unit has been lying on its side, wait 2 hours
before using. This time is required in order for the compressor
to function correctly.
• Ensure that the unit is always placed on a sturdy, flat and hori-
zontal surface.
• Ensure that the unit has a free space of at least 50 cm on each
side.
• Do not install, operate or store the device in a room smaller
than 10m².
• Make sure that the plug and socket remain visible and acces-
sible at all times.
• Do not place any objects in front of the air conditioning unit.
• Never leave a functioning device unsupervised, not even for
a moment!
• Do not use the air conditioning unit in the vicinity of flammable
or explosive substances or fuels. Never use any paint, cleaning
sprays, anti-insect sprays or similar near the unit; this could
deform the plastic or cause electrical damage.
• Never block the grilles for incoming or outgoing air (not even
partially). Never insert objects such as pens into the device
via the grilles and ensure that the ventilator does not become
blocked.
• Children, disabled persons and pets should be supervised to
ensure that they don't play with the appliance.
• This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Avoid children coming into contact or playing with the device.
• Do not turn on the appliance if you have discovered damage to
the appliance, cord or plug, if the appliance is malfunctioning,
if it has been dropped or if there are signs of any other defect.
Return the complete product to the vendor or to a certified
electrician for inspection and/or repair. Always ask for original
parts. The appliance (incl. cord and plug) may only be opened
and/or repaired by properly authorised and qualified persons.
Electrical safety
• The air conditioning unit is only suitable for indoor use.
• Only use the plug that is installed on the device in the factory
and no other form of connector!
• The appliance shall be installed in accordance with national
wiring.
• Before use, check whether the socket voltage that you will
be using corresponds to the specification plate on the unit.
Damage caused by incorrect voltage is not covered by the
guarantee!
• If the air conditioning unit is not in use or you are cleaning or
carrying out maintenance on it, turn it off and remove the plug
from the socket. Always turn off first and then remove the plug!
• Also, when you are going to use the device: first insert the
plug into the socket, then switch the device ON and then use
the control button!
• Do not use the air conditioning unit in a damp or wet envi-
ronment and never splash water, oil or any other liquid onto
the device.
• Avoid the use of extension cables if you can. If this is una-
voidable, use a cable with sufficient capacity (at least 3 x 1.5
mm²) and do not let it cross any walking routes!
• Do not move the unit by tugging on the electric cable and never
remove the plug from the socket by pulling the cable. Do not
damage/deform/change the electrical cable and/or plug. This
A227789
may damage the device or cause electrocution.
• Switch the device off immediately and pull the plug out of the
14000 BTU/hr
socket if you hear strange sounds, smell odours or see smoke.
4000 Watt
Do not use the unit if the electrical cable, plug or device is
damaged or broken. The device, plug and/or cable must be
1538 Watt
repaired/replaced by an electrician or another suitably quali-
fied person. Repairs by unqualified persons will result in the
450 m³ / hr
guarantee becoming null and void and could lead to dangerous
situations!
220–240V / 50Hz
Safety in relation to coolant R290
• Read these warning carefully.
65dB(A)
• This device contains the coolant R290. R290 is a coolant that
complies with the relevant European Directives. Never perforate
R290 / 210 gr.
the coolant circuit. R290 is flammable (GWP 3)!
• Never use substances other than those recommended by the
IP20
manufacturer for the defrosting process.
• This device must be used and stored in a room that does not
3
contain sources of ignition, such as open flames or gas and
electrical devices in operation.
• Do not perforate any of the components of the cooling circuit
18 - 35°C
and do not set light to the device.
• If the device is installed, working or stored in an un-ventilated
you must take measures to prevent fire or explosions caused
by leaked coolant. Ensure that there are absolutely no sources
26 kg
of ignition (such as fire, heaters, sparking electrical equipment,
lit cigarettes, etc.) in the same room!
44 x 33,5 x 71,5 cm
• The device must be stored in such a way that mechanical
defects are prevented.
• R290 is odourless, which means that you cannot smell leaks!
• Persons working on the cooling circuit must be in possession
of the correct qualifications that state the person in question is
competent to use coolant in accordance with a special evalua-
tion that is recognised by the sector association.
• The repairs must be executed on the grounds of the recom-
mendations of the manufacturer of the device. Maintenance and
repairs that require the assistance of other qualified persons
must be executed under supervision of someone who is specia-
lised in the use of flammable coolant.
For maximum effect
• Never exceed the recommended area to be cooled.
• Do not place the unit in the vicinity of a heat source, not in the
same room as a tumble dryer and not in direct sunlight.
• Close windows and doors.
• Keep curtains or hatches closed during the sunniest hours in
the day
• Keep filters clean
• Modify temperature and ventilation settings once the area has
reached the required condition.
Figure 1 of this product can be found at the end of this
document.
1
2
3
4
5
6
7
8
9
10
11
12
13
DESCRIPTION
Front panel
Air outlet
Control panel
Handle
Air inlet
Electrical cable with plug
Water drain - constant
Hot air exhaust hose connector
Air inlet
Storage point for electrical cable and plug
Water drainage point
Castors
Remote control
Accessories
Figure 2 of this product can be found at the end of this
document.
A
Outlet hose hot air
B
Connector window panel
C
Connector air conditioner
D
Window panel
INSTALLATION
A227789 is a mobile air conditioning/dehumidifying unit that can
be moved from room to room. Install as follows:
• Remove all packaging material and ensure that the unit remains
in an upright position.
• Before use, check that all accessories are present and that there
is no damage to the accessories or the unit itself. Do not use a
damaged unit; take it back to your supplier!
• Place the unit on a sturdy, flat, dry and horizontal base near an
electrical socket and a discharge point for hot air, e.g. a window
that can be opened slightly. Make sure that the unit has at least
50 cm of free space on all sides and take all safety instructions
into account.
• To dehumidify you now connect a water drainage hose to the
water drain - constant (7).
• This hose should lead to a bucket or drain. The hose should not
run upwards! Your unit is now ready for use.
• In order to use the cooling function, you do not need to connect
the water drainage hose. Place window panel in the window
opening, see diagram. The length of the window panel can be
adjusted from 67.5 to 123 cm.
Figure 3 of this product can be found at the end of this
document.
• Screw on the connector for the air conditioner on one end and
the connector for the window panel on the other end of the
outlet hose.
• Slide the connector for the air conditioner into the appropriate
slot on the rear of the unit.
• Secure the other end of the outlet hose in the window panel
opening so that it can remove hot air outside.
• You can also hang the outlet hose out of an open window; this
method is less efficient however.
• Avoid bends or pinches in the pipe. These will lead to a build up
of damp, waste air which can cause leaks, overheating or lead
to the air conditioning unit switching off.
• Warning! Do not use your air conditioning unit until it has been
installed according to the instructions above!
• Warning! Ensure that water cannot penetrate the device!
• Warning! The length of the discharge pipe corresponds to
the technique that is used in this air conditioning unit. Do not
replace or extend it using another pipe as this could have a
negative impact on the effectiveness of the unit. The hose can
be stretched but must be kept as short as possible in order to
ensure optimum functioning.
• Don't forget about preventing access to burglars!
OPERATION
Figure 4 of this product can be found at the end of this
document.
The control panel and remote control have the same buttons. This
means that they give the same commands. The control panel also
has lights that indicate the mode set. The control panel also has a
W.F. light (water tank full) and a display that shows the tempera-
ture and timer settings.
Before using the air conditioner, check:
• That it has been installed according to safety instructions
• That it is not damaged or broken
• That the electrical socket that you wish to use has the same
voltage as is given on the unit's specification plate (220-240V
/ 50Hz)
• That no other devices are connected to the same socket
If this has all been checked, you can insert the plug into the socket.
Start the unit by pressing on the POWER button.
Use the MODE button to choose a specific function: automatic
function, cooling, dehumidifying or ventilate. Every time you press
the button, the function changes. The light on the control panel
shows which function is active. If you are cooling or dehumidifying,
wait for up to 3 minutes after switching on or off before switching
the unit on or off again. The compressor needs this time to recover.
Automatic cooling
Å Press MODE until the AUTO indicator lights up.
The device will, depending on the ambient temperature, automati-
cally select a desired temperature with the accompanying function:
cool, dehumidification or ventilation. This indicator light will also
activate.
Ambient
Mode
temperature
< 23°C
Ventilation (fan)
23°C ≤ amb.
Dehumidification
temp ≤ 26°C
(dehum)
≥ 26°C
Cooling (cool)
Desired
temperature
21°C
23°C
25°C