Place Of Installation, Positioning And Fire-Prevention Safety - Ravelli HR EVO 290 Manual De Instalación, Uso Y Mantenimiento

Caldera de pellets
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Rev.1 16/03/2018
ENG
Pag.60
Make sure the equipment used for lifting and transport can take the boiler's weight, specified on the data plate and in this manual.
During transport and storage, avoid exposure to rain or persistent humidity.
The boiler must only be moved in a vertical position by forklift, resting on the base
Use suitable equipment to remove the boards or wooden parts of the boiler packing.
Disposal or recycling of the packing must be done by the end user, complying with local regulations on waste and keeping it
out of the reach of children or disabled persons.
The boiler must always be moved vertically. Particular care must be taken to ensure that the door and glass are protected by
mechanical shocks that compromise their integrity.

Place of installation, positioning and fire-prevention safety

After preparing the water and electrical connections (by a qualified technician), open the packing and remove the boiler from pallet.
After removing the protective packing, be careful not to damage the mechanical and electrical parts by knocking or splashing with
water.
Place the boiler in the required location, making sure it:
complies with the requirements of the regulations in force;
complies with correct operation of the unit;
is possible to operate and service the unit in any position needed to do the work;
is provided with adequate ventilation from the outside;
is provided with a suitable fume exhaust system;
is provided with an approved, grounded power socket.
Set the boiler down on the floor very carefully without any bumping and position it in the required place. Make sure the floor can take
its weight, otherwise see a specialized technician.
After positioning the boiler, fit the 4 feet (included the bag supplied) which stabilize the unit if the floor is not perfectly flat: to fit and/or
adjust the height of each foot, tilt the boiler where and as necessary.
The unit is suitable for operation in technical environments with min. temperature not below 0°C; it comes complete with an antifreeze
function that activates the heating pump for system water temperatures below 6°C, safeguarding: heating chamber, heating/DHW
circuit. The antifreeze function is active only when the boiler is electrically powered.
HR EVO 290 - 350 - 390
use and maintenance manual
Positioning feet

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hr evo 350Hr evo 390

Tabla de contenido