Head Assembly/Electrode Replacement - Riello G30 MRBLU CF Instrucciones Para La Instalación, Uso Y Mantenimiento

Quemadores de gasóleo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Use the template 2) supplied (Fig. 26) to check that the
head assembly is placed correctly 1), following the instruc-
tions indicated in Tab. B.
Model
G30 MRBLU
G40 - G50 MRBLU
2
A Combustion head adjustment
B Slot adjustment
A
B
D9473
Thread the wires 5) (Fig. 27) in the electrodes 12), and
check that the seal between cable-electrode terminals is
properly fixed (if necessary, fasten the cable terminals);
then, protect the terminals with the insulating tubes.
D9491
Fit the blast tube 2) (Fig. 24) and fix it with the screw 3) with
a tightening torque not exceeding 0.8 Nm, being careful to
adjust the opening of slots as indicated in Tab. A page 16
(use the template supplied) (Fig. 26).
Maintenance
mm
2,5 mm
4 mm
Tab. B
1
m m
Fig. 26
5
12
Fig. 27
Fix the sleeve 11) (Fig. 28) following the indications in the
figure.
9.3.3

Head assembly/electrode replacement

To access the head assembly/electrodes, follow these instructions:
remove the flange-fixing nut and pull out the burner;
hook the burner onto flange 1) (Fig. 29), undo the screws 3)
and pull off the blast tube 2);
loosen the screw 8) and take out the combustion head 7)
from the nozzle holder 9) trying to slide off the wires 5) from
the electrodes;
replace the combustion head 7);
refit in the reverse order as described in paragraph
9.3.2 "Nozzle replacement" at page 22.
7
1
D9496
23
GB
11
D9499
Fig. 28
2
8
5
3
Fig. 29
20011755