Installation
Please follow this sequence when installing the Uponor Smatrix Remote
Access Module R-56 SMS and public thermostat T-163/T-143.
Note! The public thermostat T-163/T-143 switch settings must be done
before the thermostat is registered to the Uponor Smatrix Base/Wave/
Wave PLUS Controller X-145/X-163/X-165 (controller).
• Set the switches on the public thermostat T-163/T-143 as shown in
picture C.
• Install the SIM card in the remote access module R-56 slot on the
right side of the unit, see picture D. Note! Use mobile phone to de-
activate PIN code.
• Mount the antenna.
• Fix the public thermostat T-163/T-143 and the remote access
module R-56 to the wall.
• Connect the sensor input on the public thermostat T-163/T-143 to
the relay output on the remote access module R-56, see picture E.
• Place the batteries in the public thermostat T-163.
• Replace the remote access module R-56 cover and connect the
power supply.
• Register the thermostat to system channel 5 in the Uponor Smatrix
Base/Wave/Wave PLUS controller. Please see the controller manual
for further instructions.
• The system should now be manually operable. Test that pressing the
remote access module R-56 On/Off button activates ECO mode in
the controller.
U P O N O R S M AT R I X R E M O T E A C C E S S M O D U L E R - 5 6 S M S
UK
3